48
Second period HW switched off
[h:min.]
P 125
Setting the time of switching -off the second period for HW heating
Desired HW temperature in the second period
[
o
C]
P 126
Setting the desired HW temperature in the second period
Note: In application with HW thermostat the value must correspond to the
temperature set on HW thermostat.
Third period HW switched on
[h:min.]
P 127
Setting the time of switching –on the third period for HW heating
Third period HW switched off
[h:min.]
P 128
Setting the time of switching –off the third period for HW heating
Desired HW temperature in the third period
[
o
C]
P 129
Setting the desired HW temperature in the third period
Note: In application with HW thermostat the value must correspond to the
temperature set on HW thermostat.
HW Hysteresis
[
o
C]
P 130
This value relates to the desired HW temperature. In case the HW temperature
has dropped by this value below the HW set desired value HW heating will start
again.
HW time schedule reset
P 131
By this parameter activation the time regime returns to the manufacturer’s setting
Value 1 – activation
Feeder runtime
[s]
P 140
Feeder runtime in automatic regime
Feeder X1 lignite
[%]
P 150
It regards the percentage value of output.
The value 0 represents the min. output and the feeder standstill time of parameter
151 is assigned to this value
Note: This parameter cannot be changed
Feeder Y1 lignite
[s]
P 151
Setting the feeder standstill time for HU fuel relating to 0% output
Feeder X2 lignite
[%]
P 152
It regards the percentage value of output.
The value 33 represents the 33% output and the feeder standstill time of
parameter 153 is assigned to this value. Note: This parameter cannot be changed
Feeder Y2 lignite (HU)
[s]
P 153
Setting the feeder standstill time for HU fuel relating to 33% output
Feeder X3 lignite
[%]
P 154
It regards the percentage value of output.
The value 33 represents the 66% output and the feeder standstill time of
parameter 155 is assigned to this value Note: This parameter cannot be changed
Feeder Y3 lignite
[s]
P 155
Setting the feeder standstill time for HU fuel relating to 66% output
Feeder X4 lignite
[%]
P 156
It regards the percentage value of output.
The value 33 represents the 100 % output and the feeder standstill time of
parameter 157 is assigned to this value. Note: This parameter cannot be changed
Feeder Y4 lignite
[s]
P 157
Setting the feeder standstill time for HU fuel relating to 100% output