Technical parameters 

Designation  AkuECONOMY 300 L 

Volume 

300 

Maxim. permissible temperature  

o

95 

Maxim. permissible pressure 

bar 

Dimensions 

Water drain valve 

 

 

Height of connection for boiler water 

GS1 

mm 

220 

Height of connection for boiler water 

GS2 

mm 

390 

Height of connection for sensors or 
thermometer 

GS3 

mm 

500 

Height of connection for boiler water 

GS4 

mm 

730 

Height of connection for sensors or 
thermometer 

GS5 

mm 

900 

Height of connection for boiler water 

GS6 

mm 

1070 

Height of connection for sensors or 
thermometer 

GS7 

mm 

1235 

Height of connection for boiler water 

GS8 

mm 

220 

Height of connection for boiler water 

GS9 

mm 

560 

Height of connection for boiler water 

GS10 

mm 

900 

Height of connection for boiler water 

GS11 

mm 

1235 

Height of equipment  

mm 

1370 

Tank diameter (without insulation) 

Ø 

550 

Diameter with insulation) 

Ø 

700 

Insulation made of  hardened polyurethane 
foam 

 

mm 

70 

External shell  

skay 

Hydraulic connections 

Boiler water supply/ return branch of heating water 

internal  

thread 

1 1/2” 

Connections for sensor and thermometer 

internal  

thread 

1/2" 

Water drain valve 

internal  

thread 

1” 

Weight without insulation (empty)  

kg 

75 

 
 

Содержание AkuECONOMY 1000 L

Страница 1: ...Hercules U26 Návod k obsluze STORAGE TANKS AkuECONOMY 500 L AkuECONOMY 800 L AkuECONOMY 1000 L AkuECONOMY 1500 L AkuECONOMY 2000 L OPERATING AND INSTALLATION MANUAL AkuECONOMY 200 L AkuECONOMY 300 L ...

Страница 2: ...2 Table of contents page 1 Description of construction 3 2 Instructions for product disposal after its service life expiration 3 3 Guarantee 4 ...

Страница 3: ...l media e g demineralised heating water glycol etc The maximum allowable operating pressure in the tank is 3 bar 0 3 MPa In the table below there are given the values of wall thickness and material used for the manufacture of storage tanks AkuECONOMY Storage tank Tank diamete r Ø Bottom Material Shells Material Material thickness Material thickness Nominal mm Minimal mm S235JR Nominal mm Minimal m...

Страница 4: ...manual guarantee certificate Every fault must be notified immediately after having been discovered and always in writing In case of an infringement of above instructions the guarantees provided by the manufacturer will not be recognized The guarantee does not apply to faults caused by improper assembly and improper attendance of the product and faults caused by improper maintenance product damage ...

Страница 5: ...5 AkuECONOMY 200 L AkuECONOMY 300 L AkuECONOMY 500 L AkuECONOMY 800 L AkuECONOMY 1000 L AkuECONOMY 1500 L AkuECONOMY 2000 L 0 GS8 GS9 GS10 GS11 L 0 GS1 GS2 GS3 GS4 GS5 GS6 GS7 SPUST water outlet ...

Страница 6: ...m 785 Height of connection for sensors or thermometer GS6 mm 885 Height of connection for boiler water GS7 mm 220 Height of connection for boiler water GS8 mm 553 Height of connection for sensors or thermometer GS9 mm 785 Height of equipment L mm 1105 Tank diameter without insulation d Ø 550 Diameter with insulation D Ø 700 Insulation made of hardened polyurethane foam mm 70 External shell skay Hy...

Страница 7: ... mm 1070 Height of connection for sensors or thermometer GS7 mm 1235 Height of connection for boiler water GS8 mm 220 Height of connection for boiler water GS9 mm 560 Height of connection for boiler water GS10 mm 900 Height of connection for boiler water GS11 mm 1235 Height of equipment L mm 1370 Tank diameter without insulation d Ø 550 Diameter with insulation D Ø 700 Insulation made of hardened ...

Страница 8: ...mm 1385 Height of connection for sensors or thermometer GS7 mm 1615 Height of connection for boiler water GS8 mm 225 Height of connection for boiler water GS9 mm 690 Height of connection for boiler water GS10 mm 1155 Height of connection for boiler water GS11 mm 1615 Height of equipment L mm 1905 Tank diameter without insulation d Ø 600 Diameter with insulation D Ø 800 Insulation made of hardened ...

Страница 9: ...6 mm 1215 Height of connection for sensors or thermometer GS7 mm 1410 Height of connection for boiler water GS8 mm 250 Height of connection for boiler water GS9 mm 620 Height of connection for boiler water GS10 mm 1020 Height of connection for boiler water GS11 mm 1410 Height of equipment L mm 1730 Tank diameter without insulation d Ø 790 Diameter with insulation D Ø 990 Insulation made of soft po...

Страница 10: ...GS6 mm 1485 Height of connection for sensors or thermometer GS7 mm 1730 Height of connection for boiler water GS8 mm 250 Height of connection for boiler water GS9 mm 740 Height of connection for boiler water GS10 mm 1240 Height of connection for boiler water GS11 mm 1730 Height of equipment L mm 2050 Tank diameter without insulation d Ø 790 Diameter with insulation D Ø 990 Insulation made of soft ...

Страница 11: ...S6 mm 1950 Height of connection for sensors or thermometer GS7 mm 2260 Height of connection for boiler water GS8 mm 330 Height of connection for boiler water GS9 mm 1015 Height of connection for boiler water GS10 mm 1640 Height of connection for boiler water GS11 mm 2260 Height of equipment L mm 2700 Tank diameter without insulation d Ø 900 Diameter with insulation D Ø 1100 Insulation made of soft...

Страница 12: ...S6 mm 1755 Height of connection for sensors or thermometer GS7 mm 2025 Height of connection for boiler water GS8 mm 385 Height of connection for boiler water GS9 mm 930 Height of connection for boiler water GS10 mm 1480 Height of connection for boiler water GS11 mm 2025 Height of equipment L mm 2410 Tank diameter without insulation d Ø 1100 Diameter with insulation D Ø 1300 Insulation made of soft...

Страница 13: ...o Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confirms that he has received the Operating ...

Страница 14: ...arranty for the customer user Record of the carried out warranty and post warranty repairs and regular annual checks of the product Date of record Carried out activity Contractual service organization signature stamp Signature of customer ...

Страница 15: ... out according to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confirms that he has receive...

Страница 16: ...16 ...

Страница 17: ...ding to Operating and installation manual for storage tanks by a contractual service organization accredited by the manufacturer The faults must be removed by a contractual service organization accredited by the manufacturer The completeness of the supplied storage tank is guaranteed by the seller The certificate of warranty is void if not filled out The user confirms that he has received the Oper...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...20 Date of updating 46 2012 GB ...

Отзывы: