Rebuild Broken RAID 1 Array
When booting up the system, BIOS will detect if any member disk drives of RAID has
failed or is absent. If BIOS detects any disk drive failures or missing disk drives, the
status of the array will be marked as broken.
If BIOS detects a broken RAID 1 array but there is a spare hard drive available for
rebuilding the broken array, the spare hard drive will automatically become the mirroring
drive. BIOS will show a main interface just like a duplicated RAID 1. Selecting
Continue
to boot
enables the user to duplicate the array after booting into operating system.
Broken RAID 1
Critical Status
Power off and check the failed drive
A disk member of a mirroring
Destroy the Mirroring Relationship
array has failed or is not
Choose replacement drive and rebuild
responding.The array is
Continue to boot
stilling functional,but fault
tolerance is disabled.
Remaining members of the failed array
Channel Drive Name
Array Name Mode Size(GB) Status
Channel0 Device0 IC35L040AVVA07-0 Array0 ATA 100 38.34 Broken