![VGE xclear SIEVE GRAVITY FED Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/vge/xclear-sieve-gravity-fed/xclear-sieve-gravity-fed_installation-instructions-manual_1010803007.webp)
12
13
FLOATER
The Xclear Sieve floater must be filled with ± 500ml (±1 pint) of water to give it some
counterweight. Fill the gap after filling by pushing the supplied rubber cap firmly into
the hole.
MOUNTING THE FLOATER
The floater height on the supplied PVC pipe will determine the water level underneath
the sieve screen when the pump is running. You can fasten the float with the supplied
cable tie wrap. Before you secure the tie wrap, first test the correct height by just
sticking the tie wrap through the holes of the float and PVC pipe! The highest position is
for high flow rates (20-25m³/h), lowest position is for low flow rates (± 5m³/h). The PVC
pipe has 4 holes.
MOUNTING THE INNER CONTAINER
The inner container must be sealed at the pipe connections with the
supplied rubber foam rings. Fix them around the pipe connections of
the inner container and lower the container with the float pipe into the
Xclear Sieve. Firmly push the inner container into the pipe connections
for maximum sealing results. You can check with your fingers on the
inside of the container if the rubber rings are positioned correctly.
WASTE OUTLET
The Xclear gravity fed Sieve comes with a 63mm (2”) waste outlet that can be connected
to the supplied 50mm slide valve with the supplied flexible socket.
PUMP CONNECTION
The Xclear Sieve comes with a flexible reducer fitting of 90 x 63mm (3” to 2”). The
90mm/3”part fits on the pump outlet of the Xclear Sieve and the 63mm/2” part can be
used to push a 63mm/2”pipe through towards the end of the Xclear gravity fed Sieve to
prevent the pump from sucking in air bubbles.
MAINTENANCE
It is recommended to monitor the Xclear Sieve every day. Maintenance is very easy because of the waste outlet. In fact maintenance is about
two operations:
1. To remove the waste that is on the surface of the sieve (every day).
2. To remove the waste that has gone into the profile wires of the sieve (only when necessary).
1. Removing the waste that is on the surface of the sieve is very easy by opening the waste outlet and to rinse the waste away with a normal
hose pipe. Another method to have water run over the screen is to open the adjustable weir (G) which will flood the screen with water.
When the adjustable weir is in a fully open position already because of the pump speed you can push it closed for a short while and open it
again.
2. To remove the waste that has gone into the profile wires of the sieve you will need a hose pipe with a powerful spray nozzle or a high-
pressure machine. For this way of cleaning you have to place the sieve in an upright position or take the sieve out of the unit.
Note: when you use the sieve for the very first time the surface of the sieve can also be covered with a very thin film. Make
sure you will clean the sieve very thorough with alcohol before using it.
TECHNICAL SPECIFICATIONS
SIZE
MATERIAL
EXTRA INFO
HOUSING
67 x 36 x 101 cm
PE
Lid included
INLET
110 mm outer Ø
PE
2 x 110 mm (4“) inlet
PUMP OUTLET
90 mm outer Ø
PE
Comes with 90/63mm (3 x 2”) flex. fitting
WASTE
63 mm
PVC Slidevalve
Comes with 63/50mm (2 x 1½”) flex. fitting
SIEVE BEND
450 x 345 mm
SS 304
300 micron
CAPACITY
Max. 25 m³/h
WEIGHT
±15 Kg. Incl. screen
Xclear is a trademark of VGE BV Son & Breugel www.vgebv.nl copyright VGE BV version 1.01 2013