background image

On-Site Manual 

 

VEX-FLEXI-MINILINE 

 

Drawing Number: 005898 

 

Page 

1

 of 

11

 

 

 

VEX-FLEXI-MINILINE 

 On-Site Manual 

 
 
 

 

 
 
 
 
 

Please ensure you have read the following instructions thoroughly and can undertake the required 

actions before commencing installation. 

If you have any queries, please consult the Vexica Technical Support Department before 

proceeding. 

 
 
 
 

 

VERSION 1.0 

THE VEXICA GROUP LIMITED 

 TYPHOON HOUSE, MOXON WAY, SERBURN-IN-ELMET, LEEDS, LS25 6FB

 

 

Содержание VEX-FLEXI-MINILINE

Страница 1: ...re you have read the following instructions thoroughly and can undertake the required actions before commencing installation If you have any queries please consult the Vexica Technical Support Departm...

Страница 2: ...stallation 4 Bracket Installation 6 Led Ready Profile Installation 7 Wiring Instructions 8 Extending Vexica Standard Input Cables 10 Cautions 11 Scope This manual will detail the installation of a VEX...

Страница 3: ...d make sure you fully understand them Pay attention to how the luminaire is wired If you require any further guidance please contact Vexica IMPORTANT DO NOT BEND FITTINGS SMALLER THAN A 60MM BEND RADI...

Страница 4: ...ape Installation Clean the Surface or aluminium profile thoroughly with isopropyl alcohol or equivalent to ensure proper adhesion Allow this to dry properly Once the surface is free from dirt and grea...

Страница 5: ...ite Manual VEX FLEXI MINILINE Drawing Number 005898 Page 5 of 11 Peel the backing off the double sided tape and adhere to the desired surface While adhering a pressure of 10 15 N CM only is to be appl...

Страница 6: ...on Part Code 005896 Use the bracket to clamp the VEX FLEXI MINILINE Using a suitable 3M double sided tape applied as above Fix the VEX FLEXI MINILINE to the desired surface Use up to six brackets per...

Страница 7: ...le brackets clips to fix the Luminaire to the desired surface Fix mounting clips to the required surface using appropriate screws Vexica do not provide these as the type and size depends on the surfac...

Страница 8: ...ators if applicable Do not reverse polarity Always allow enough slack on the supply cable to remove luminaire from its position for any further maintenance Make sure supply cable is not in contact wit...

Страница 9: ...AIN TO RETAIN IP RATING 2 WAY TERMINATOR VEXICA PART NUMBER 001733 3 WAY TERMINATOR VEXICA PART NUMBER 005902 4 WAY TERMINATOR VEXICA PART NUMBER 000909 Vexica approved PSU LEDDriver Starter cable 24...

Страница 10: ...nnections on site always ensure the connection has an appropriate IP rating Vexica recommends the starter cables are linked to extensions cables with gel boxes When using extending sheathed cables ens...

Страница 11: ...be of the actual product supplied depending on options specified when ordering Avoid staring directly into the light beam A certified electrician should install the product following local regulations...