VEXICA FLEXI-LINE-T Скачать руководство пользователя страница 8

 

 

 

 

Drawing Number: 002105 

 

 Page 

8

 of 

12

 

 

RGB – Unsheathed – JWPF 4-Way 

Red 

RED GND 

Green 

GREEN GND 

Blue 

BLUE GND 

Black 

+24 VDC 

Table 3 

RGB – Sheathed – SSL1.2 4-Way  

Red 

RED GND 

Orange 

GREEN GND 

Yellow 

BLUE GND 

Brown 

+24 VDC 

 

 

 

 

 

 

 

 

 

RGB/RGBW Dynamic 

Red 

+24 VDC 

White 

Data 

Black 

-GND 

Table 4 

 

 

 

 

 

 

 

Vexica approved PSU/LED

 

Driver

 

Starter cable 

24 VDC (refer to Table.3)

 

Max chain of fittings 4.8m

 

Terminator 
(000909) 

 

Starter cable (up to 1m) 

24 VDC (refer to Table.4)

 

Max chain of fittings 4.8m

 

Vexica approved PSU/LED

 

Driver

 

Terminator 
(005902)

 

Содержание FLEXI-LINE-T

Страница 1: ...llowing instructions thoroughly and can undertake the required actions before commencing installation If you have any queries please consult our Technical Support Department before proceeding THE VEXI...

Страница 2: ...BW 9 Important Information 10 Extending Vexica Standard Input Cables 11 Cautions 12 Scope This manual will detail the installation of VEX FLEXI LINE T Single Colour RGB RGB DYN Tuneable White and RGBW...

Страница 3: ...nd them Pay attention to how the luminaire is wired If you require any further guidance please contact Vexica Installation Instructions IMPORTANT DO NOT BEND FITTINGS SMALLER THAN A 150MM BEND RADIUS...

Страница 4: ...ng surface Press fitting into the installed bracket until the fitting is flush on the base on the bracket Use 3 or 4 brackets per metre of light fittings depending on the bend radius minimum 150mm and...

Страница 5: ...ixture rubbing alcohol or heptane Use proper safety precautions for handling solvents It may be necessary to seal or prime some substrates before bonding a Most porous or fibred materials e g wood wil...

Страница 6: ...eciding location Make sure all connections made are tight with no loose strands and with appropriate IP rated connectors Do not reverse polarity Always allow sufficient slack on the supply cable to re...

Страница 7: ...g Single Colour Red 24 VDC Black GND Table 1 Tuneable White Red 24 VDC Black CH 1 White CH 2 Table 2 Vexica approved PSU LEDDriver Starter cable 24 VDC refer to Table 1 Max chain of fittings 4 8m Term...

Страница 8: ...Red RED GND Orange GREEN GND Yellow BLUE GND Brown 24 VDC RGB RGBW Dynamic Red 24 VDC White Data Black GND Table 4 Vexica approved PSU LEDDriver Starter cable 24 VDC refer to Table 3 Max chain of fitt...

Страница 9: ...D OF A CHAIN TO RETAIN IP RATING 2 WAY TERMINATOR VEXICA PART NUMBER 001733 3 WAY TERMINATOR VEXICA PART NUMBER 005902 4 WAY TERMINATOR VEXICA PART NUMBER 000909 6 WAY TERMINATOR VEXICA PART NUMBER 00...

Страница 10: ...n appropriate IP67 rated junction All cable extensions must follow guidelines for voltage drops and proper amperage handling Ensure that all electrical input feeds use Vexica original input cables onl...

Страница 11: ...always ensure the connection has an appropriate IP rating Vexica recommends the starter cables are linked to extensions cables with gel boxes When using extending sheathed cables ensure that the oute...

Страница 12: ...RIOD CAUTION All images are representative and may not be of the actual product supplied depending on options specified when ordering Avoid staring directly into the light beam The product should be i...

Отзывы: