Lava Rock and Ember Material

1.  For all models, place lava rock along sides and 

front of firebox bottom in areas that are visible. It 

is not necessary to use all lava rock provided. 

NOTICE:  Do  not  put  lava  rock 

on  or  under  burner.  Placing 

lava rock on burner could cause 

performance problems.

2.  Pull ember material apart into pieces no larger 

than a dime. Place loosely and directly onto 

exposed section of front burner and along space 

between burner and grate prongs. These will cre-

ate glowing ember appearance as flame touches 

ember material. Do not block air slots by using 

too much ember material in one area. It is not 

necessary to use all ember material provided. 

3.  When lava rock and ember material are in 

place, close and latch glass door and secure 

louvers in place.

  WARNING:  The  glass  door 

must be securely in place before 

operating fireplace. Do not oper-

ate fireplace if glass is missing 

or broken.

DECORATIVE FACING

Any noncombustible material may be used as fac-

ing (glass, tile, brick, etc.) as long as the proper 

clearances are observed (see 

Clearances to Com-

bustibles

, page 4). Louvered openings must not 

be obstructed and upper and lower panels must 

remain accessible for service. Use only heat-re-

sistant, noncombustible mortar or adhesive when 

securing decorative facing materials.

FACE EXTENSION FOR MODEL 
CD32M ONLY

Model CD32M comes equipped with a front face 

extension. The front face extension would add 

1

/

2

" to the width and 3/4" to the height of the 

fireplace face.
To install face extension:
1.  Remove existing screws from front face as-

sembly as shown in Figure 29.

2.  Align holes on top face extension with holes on 

top side of front face assembly and secure with 

screws previously removed (see Figure 29). 

INSTALLATION 

Continued

3.  Align holes on right face extension with holes 

on right side of front face assembly and secure 

with screws previously removed (see Figure 

29). Do the same for left side.

4.  Secure top face extension with left and right 

face extensions with two sheet metal screws 

(see Figure 29).

Figure 29 - Front Face Extension, Model 

CD32M Only

BURNER FLAME 

ADJUSTMENT

The burner flame adjustment (shutter opening) has 

been factory preset (for natural gas) to the proper 

air-to-gas ratio. This ratio results in an even, clean 

burning flame across the burner (see Figure 30).

Figure 30 - Burner Flame Patterns

CORRECT

INCORRECT
CLOSE 
SHUTTER

INCORRECT
OPEN 
SHUTTER

Short, Sharp, Blowing Flame

Long, Blue Flame with Yellow Tips

Long, Uneven, Yellow Flame

Side Face 
Extensions

Top Face 
Extension

Содержание CD32Ml

Страница 1: ...h do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installa...

Страница 2: ...d the Manufactured Home Construction and Safety Stan dard Title 24 CFR Part 3280 in the United States or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This replace is only for use with the...

Страница 3: ...uring safe and continuous operation of the replace Consult the local building codes as to the particular requirements concerned with the instal lation of all factory built replaces This replace when i...

Страница 4: ...N PREPARATION CAUTION Do not block required air spaces with insula tionoranyothermaterial Donot obstruct the effective opening of the appliance with any type of facing material CLEARANCES TO COMBUSTIB...

Страница 5: ...which could cause a re WARNING Horizontal sec tions of this vent system require a minimum clearance of 2 from the top of the pipe and 1 mini mum to the sides and bottom Vertical sections of this syste...

Страница 6: ...ved driveway located on public property 84 inches 213 4cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a roof shall extend a minimum of 24 inches 61cm above...

Страница 7: ...bly must be venteddirectlytotheoutside The venting system must NEVER be attached to a chimney serving a separatesolidfuelburningappli ance Each gas appliance must use a separate vent system Do not use...

Страница 8: ...mination that is over 3 ft support the pipe every 3 ft using metal wall straps Vertical to horizontalpipemustbekeptata1ft to4ft ratio with a maximum run of no more than 20 ft If an offset is necessary...

Страница 9: ...in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas sup ply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at...

Страница 10: ...a leak Correct all leaks at once Do not operate any appliance if a leak is detected INSTALLATION Continued Figure 13 Gas Line Routing Gas Routing Right Side Not Shown Side of Fireplace Front Face Figu...

Страница 11: ...place Models CD32M and CD36M A Series 1 Place log 1 back log on top of grate as shown in Figure 18 for the CD36M A Series Log 1 will go in front of the metal partition on grate see Figure 18 Make sure...

Страница 12: ...log 3 rear log onto pins on rear of grate see Figure 25 4 Place log 4 crossover log onto pins from both logs 2 and 3 see Figure 26 Figure 23 Installing Log 1 Model CD42M A Figure 24 Installing Log 2 M...

Страница 13: ...els must remain accessible for service Use only heat re sistant noncombustible mortar or adhesive when securing decorative facing materials FACE EXTENSION FOR MODEL CD32M ONLY Model CD32M comes equipp...

Страница 14: ...necessary Turn off gas and remote switch before servicing appliance Any safety screen or guard removed for servicing the replace must be replaced prior to operation Have a quali ed agency periodically...

Страница 15: ...etting 12 Turn on all electric power to the appliance Note It is recommended that you maintain the gas control knob in the full OFFposition during lengthy periods of seasonal non usage OPERATING FIREP...

Страница 16: ...ll the identi cation label enclosed with gas valve regulator to the valve body where it can easily be seen see Figure 36 WARNING Theconversionkit must be installed by a quali ed servicetechnicianinacc...

Страница 17: ...ement on thermocouple 3 Ensure the connection be tween valve and thermocouple are tight and secure 4 Check thermocouple with millivolt meter Take reading at thermocouple terminals of gas valve with re...

Страница 18: ...1916 01F 18 6 7 19 18 10 12 23 24 34 2 11 17 8 21 2 21 6 21 4 21 5 21 3 21 1 1 13 9 16 3 14 4 20 15 5 15 42 40 35 36 22 37 39 38 25 41 26 30 27 28 29 33 31 32 ILLUSTRATED PARTS BREAKDOWN MODELS CD32M...

Страница 19: ...ssover Log Log 4 1 21 5 109405 01 107348 01 Left Top Log Log 5 1 21 6 109408 01 107347 01 Right Top Log Log 6 1 22 11102 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 11105 Screw 10 x 1 2 Zinc 9 24 11179...

Страница 20: ...com 111916 01F 20 ILLUSTRATED PARTS BREAKDOWN MODEL CD42M A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40 36 30 27 28 6 7 19 18 10 12 2 11 17 8 20 1 4 13 16 3 14 15 5 15 9 212 21 3 21 6 21 7 2...

Страница 21: ...over Log Log 4 1 21 5 109399 01 Top Center Log Log 5 1 21 6 109400 01 Top Left Log Log 6 1 21 7 109401 01 Top Right Log Log 7 1 22 11102 Screw 8 32 x 3 8 PPH Zinc 2 23 11105 Screw 10 x 1 2 Zinc 9 24 1...

Страница 22: ...P Manifold Pressure 10 w c 10 w c 10 w c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c WIRING DIAGRAM Thermocouple Incoming Main Gas Supply Piezo Ignitor Control Valve Electrical Rating 120v 6...

Страница 23: ...2M 109479 01 CD32M SERIES BK BLOWER KIT REGULAR TRANSMITTER TRANSMITTER RECEIVER RECEIVER TRANSMITTER STANDARD REMOTE CONTROL KIT P N 14187 MILLIVOLT ONLY RECEIVER AND TRANSMITTER RECEIVER P N 00825 E...

Страница 24: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111916 01 Rev F 04 05 111916 01...

Отзывы: