![Vexar CD32M-B Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/vexar/cd32m-b/cd32m-b_owners-manual_1010622022.webp)
www.desatech.com
119212-01B
22
Figure 48- Installing New Parts for Gas
Control Valve Conversion
HI
LO
OF
F P
I
LO
T
ON
Mounting.
Screws
Rubber.
Gasket
Identification
Label
gAS cOnverSiOn
Continued
CONVERTING CONTROL VALVE
Convert. gas. control. valve. by. swapping. out.
valve.regulator.portion.of.gas.valve.
1.. Using. a. TORX. T20. or. a. slotted. screw-
driver,.remove.and.discard.three.mounting.
screws,.pressure.regulator.tower.and.dia-
phragm/spring. components. (see. Figure.
47).
2.. Insure. that. rubber. gasket. is. properly.
positioned. on. new. pressure. regulator.
assembly..Install.new.pressure.regulator.
assembly. to. valve. using. new. mounting.
screws.supplied.with.kit..Tighten.screws.
securely. (approximately. 25. in/lb).. See.
Figure.48.
3. Install identification label enclosed with
gas.valve.regulator.to.valve.body.where.
it.can.easily.be.seen.(see.Figure.48).
WARNING: The conversion
kit must be installed by a quali
-
fied service technician in accor
-
dance with the manufacturers
instructions and all applicable
codes and requirements of the
authority having jurisdiction. If
any information is these instruc-
tions is not followed correctly,
a fire, explosion or production
of carbon monoxide may result
causing property damage, per
-
sonal injury or loss of life. The
qualified service technician is
responsible for the proper instal
-
lation of this conversion kit.
HI
LO
OF
F P
I
LO
T
ON
Figure 47- Removing Parts for Gas
Control Valve Conversion
Diaphragm/
Spring.
Components
Mounting.
Screws
Pressure.
Regulator
Tower