When the below problems occur,hire professional technician.

Problem

Cause

Solution

Voltage too low Voltage too low

Install a voltage stabilizer.

Voltage too high Voltage too high

Install a voltage stabilizer.

No display while
machine turned
on

1. Out of power,socket not
well plugged.
2. Stabilizer not well
connected,or display not well
connected
3. Fuse broken
4. PCB broken

1. Check if power supply is
normal.
2. Reconnect wires.
3. Solve the abnormality and
replace with the same
specification of fuse.
4. Check PCB

Display not
clearly

Display and motherboard not
well connected.
Motherboard malfunction

Reconnect display to the
motherboard well.
Check motherboard.

Ice cream won't
come out

1. No mixture inside
2. Mixture contains too much
water.

1. DO NOT turn to freeze mode
when no mixture inside.
2. Shut down for 30 minutes,
then restart.Please make mixture
according to the right proportion.

Ice cream is too
soft

1. Mixture contains too little
water.
2. Insufficient heat
dissipation space
3. Hardness set too low
4. Cylinder lack of mixture

1. generally speaking:1kg powder
to 2.5-3kg water
2. Air outlets of the machine
should be at least 1m away from
walls or any other barriers,other
sides should be at least 0.5m
away from any barrier
3. Increase hardness value
4. Pour in mixture.

Leakage

1. Tighten bolt is not
tightened
2. Apron misalignment
3. Apron damage

1. Tighten the tighten bolt
2. Put the apron in place
3. Replacing aprons

9.Repair

1)Please disconnect power before installing or wiring,always follow the circuit
diagram,and make sure the power supply is in accordance with that on the
nameplate.
2)Please hire a professional electrical technician for wiring.
3)Make sure all terminals are firmly connected to connectors.
4)Keep hands,fluid or any foreign objects off the PCB,and at least 6mm away from
the panels,or else may result in short-circuit and fire.

Содержание ZM-A168

Страница 1: ...ICE CREAM MACHINE MANUAL...

Страница 2: ...r more than 5 hours before using There must be a free space more than 50cm left on both sides of the machine for heat releasing Please make sure both cylinders to be filled with stuff before using nei...

Страница 3: ...eak from it during washing or making ice cream Notice sensor plate MUST BE on top of all valve stems see right photo Install the handles to the valve stems one by one in the mean time slowly push the...

Страница 4: ...der the nozzle press the handle down slowly rotate the cone in hand press the handle back to stop 6 How to Operate 1 Parameter description Corresponding parameter name Name Default value unit A168 A20...

Страница 5: ...the material cylinder is higher than the set temperature 2 degrees the stirring motor starts the balance valve starts the delay main press starts and the balance valve stops When the material cylinder...

Страница 6: ...all 4 bolts from the discharger unload the discharger then disassemble all components from the discharger B Take off the pin handles valve stems and silicone O ring C Take our the beater disassemble t...

Страница 7: ...t Please make mixture according to the right proportion Ice cream is too soft 1 Mixture contains too little water 2 Insufficient heat dissipation space 3 Hardness set too low 4 Cylinder lack of mixtur...

Страница 8: ...ure sensor Level check Material cylinder temperature sensor High pressure switch Discharge switch Air pump Output of main press Output of mixer motor Fire wire Zero line switch Precooling press Balanc...

Отзывы: