• Remove pump lid and Strainer.
• Remove clip-bayonet (part# 4 in the parts list).
• Remove the pump strainer body from the pump housing.
• Unscrew the 8 bolts.
• Turn the discharge port to be horizontal.
• Screw back the 8 bolts.
• Re-install the pump strainer body.
• Buckle up the clip-bayonet.
• Put Strainer back into the pump strainer body.
• Fasten pump lid
06
Make sure that the electrical supply available is suitable for the motor’s voltage, phase, and cycle.
Voltage from the power must be in the range from 90% to 110% of the motor nameplate rated voltage.
Otherwise, the motor may overheat and result in overload tripping and reduced component life.
Install, ground, bond, and wire motor in accordance with local or NEC requirements.
The motor should be grounded permanently by connecting the ground terminal to the electrical
service ground.
Bond motor to pool structure. Bonding will connect all metal parts within and around the pool with a
continuous wire. Bonding reduces the risk of current passing between bonded metal objects, which
could potentially cause electrical shock if grounded or shorted.
Pump discharge port can be turned to horizontal: