Pj20 tracer
Classification:
Restricted
Manuale utente
Rev 0.1 draft of 18.05.2020
Page 5 of 15
Figure 3
– Device list
By clicking on "Initialize" the device is initialized, while through the "Initialize & Configure" button
(Figure 4 - Initialization and configuration), it is possible to configure the following operating
parameters (Figure 5 - Operating parameters):
•
Profile: allows you to choose between the fast response mode to enable the device to search
for other nearby tags every 2 seconds (lower latency in the response, but higher battery
consumption) and the battery save mode, to search for nearby devices every 4 seconds
(higher latency in alarm signalling, but with a simultaneous increase in battery life);
•
Flash storage: allows you to set the minimum time interval for saving contact events;
•
Contact distances: it is possible to set the maximum distance values at which the pre-alarm
and alarm condition is signalled (it is recommended not to change the default values);
•
Alarm and Pre-Alarm: it is possible to enable the notification type (led, buzzer, vibration) both
for alarm and for pre-alarm;
•
Advanced: it is possible to enable / disable the contact data log and the device encryption data
packet (it is recommended not to change the default values).
Following the first initialization, it is possible to change the operating parameters through the
"configure" button.
After carrying out the initialization operations, it is necessary to click on the “Start Scan” button to
update the list with the devices status.