VETEC P1001/6-P Скачать руководство пользователя страница 41

41

Waste  Electrical  Electronic  Equipment  (WEEE)

In Europe, this equipment must be disposed of in accordance with European
Parliamentary Directive 2002/96/EC

This directive encourages recycling and the reduction of waste materials in the
environment.

This means it must be sent to an approved recycling plant if you want to dispose of it.

It must not be thrown away with general rubbish.

If you are unable to dispose of this item locally, you may send it to us for recycling.

   Conditions:

1. We will only accept items of our manufacture.

2. You must pay for the transport of the goods to us.

3. We will only accept items if they include a signed declaration by an authorised
     person in your organisation, stating that :-

i.

The item is safe to handle and has no contaminants which may be
harmful to health.

ii.

You wish us to dispose of or destroy the item(s)

Содержание P1001/6-P

Страница 1: ...direct sunlight Adjustable menu timeout delay to suit new and experienced users Choice of Basic or Advanced menu in standard model Outputs selectable from nett or gross Real Time clock option DIN Rail...

Страница 2: ...foregoing warranty shall not apply to defects resulting from 1 Improper or inadequate maintenance by the buyer 2 Unauthorised modification or misuse 3 Operation outside the environmental specification...

Страница 3: ...s 27 Logic Input connections Front Buttons 28 Factory defaults 29 CalibrationAudit number 29 Signal Filtering Averaging 30 31 Last Digit rounding 32 Scale Factor adjustment 33 OffsetAdjustment 34 Menu...

Страница 4: ...rs fromelectric shock We designed this meter for Pollution Degree 2 environments only Power supplies to this equipment must have anti surge T fuses rated at 400mA for 230V supply 400mA for 110V supply...

Страница 5: ...hutdown periods you may have to to wait several weeks for an equivalent replacement or we may have no stock at the time you urgently need it You mayalso needto pay extra carriagecharges ifyou wanta fa...

Страница 6: ...240 VAC or 11 30VDC These meters are designed to mount into a protective enclosure which will protect users from contact with power and signal wiring Theseunits mustbe installedfully assembled and mus...

Страница 7: ...of meter U Bracket Bracket screw 1 of 2 Left side of meter case U Bracket Bracket screws U Bracket Bracket screws Slide the meter with gasket into the panel cutout Securing into the panel Re fit the...

Страница 8: ...using the 4 buttons Output functions include isolated 16 bit 4 20mA 0 10V 10 to 10V RS232 RS485 and up to 4 alarms with a wide choice of alarm functions Install the meters in a suitable protective ele...

Страница 9: ...sealed IP65 all round and is supplied with the meter in stalled for you to wire to via 3 cable glands It comes complete with SPC4 splashproof cover We also offer a dual version of this enclosure which...

Страница 10: ...5mm2 Tighten screw terminals to 7 0 lb in torque 0 8 Nm torque Cable insulation voltage rating Cables shall have an insulation voltage rating of at least 380V continuous Wire preparation We recommend...

Страница 11: ...enif outputoptionsarenot installed Refertoratinglabel toseeinstalledoptions Class II Installation Not used Fuse Switch Circuit breaker Power Customer supplied disconnection and overload protection dev...

Страница 12: ...cancelled Mixing destinations carelessly amongst the twisted pairs can actually worsen noise performance 3 The cable should be routed away from noisy wiring and devices such as power feeds frominverte...

Страница 13: ...several displays to several sensors please be sure to use one twisted pair for each display and sensor Do NOT use a wire from one pair for signal positive and a wire from another pair for signal nega...

Страница 14: ...Easy orAdvanced mode How to choose menu mode Set1 Set2 Output Alarms Digit OK Max Min Reset Lockout Switch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press brie...

Страница 15: ...witch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Display shows UI Eng Default for User Interface English or UI FrA for User Interface French 1 2 3 Set1 Set2 Outp...

Страница 16: ...ess of the UP button will select a newbrightness level There are 7 brightness levels to choose from Default Full brightness Set1 Set2 Output Alarms Digit OK Max Min Reset Press to accept 1 2 3 Done Di...

Страница 17: ...signal level How to choose a calibration method Lockout Switch must be OFF Press 3 seconds Set1 Set2 Output Alarms Digit OK Max Min Reset Press to select dirECt or thEor Display shows CAL Src then dIr...

Страница 18: ...et1 Set2 Output Alarms Digit OK Max Min Reset Apply the highest calibration signal you can achieve ideally 100 of system capacity You can use less but you will get better accuracy with higher signals...

Страница 19: ...OK Max Min Reset Lockout Switch must be OFF Set1 Set2 Output Alarms Digit OK Max Min Reset Apply the lowest calibration signal you can achieve ideally 0 of system capacity Press OK Set1 Set2 Output Al...

Страница 20: ...Alarms Digit OK Max Min Reset If the display shows Lin OFF press Set2 button briefly so that the display shows Lin On then press OK Set1 Set2 Output Alarms Digit OK Max Min Reset 1 2 3 4 Set1 Set2 Out...

Страница 21: ...button until the display is set as required Press OK when done The display will show Add Pt Press OK if you want toAdd another calibration point you will repeat the previ ous steps each time incremen...

Страница 22: ...0mA Set1 Set2 Output Alarms Digit OK Max Min Reset Press to accept Set1 Set2 Output Alarms Digit OK Max Min Reset Display now shows rd Hi briefly You can now specify the maximum reading and decimal po...

Страница 23: ...e UP or DOWN arrow to increase or decrease each digit s value as re quired eg set 000 000 if your display range is 0 to 100 000 Theoretical Calibration Low end calibration This is when you type in the...

Страница 24: ...hen press OK Set1 Set2 Output Alarms Digit OK Max Min Reset 1 2 3 4 The display will show In 00 followed by an editing screen Here you can enter your first calibration input signal level using DIGIT b...

Страница 25: ...utton and increase or decrease each digit s value using the UP or DOWN button until the display is set as required Press OK when done The display will show Add Pt Press OK if you want toAdd another ca...

Страница 26: ...ings less than 8 least significant counts The corrected value is stored in non volatile memory so that any drift trend will be re ap plied after you have switched off the meter Lockout Switch must be...

Страница 27: ...on for Contact Closure 1 After you have set CC 1 you will get the prompt CC 2 to allow you to set Contact Closure 2 function and when you have set CC 2 you will get the prompt CC 3 to allow you to set...

Страница 28: ...anel Tare Peak Valley and Reset buttons also Or simply link NPN could be opto isolators if you need the logic control lines to be galvanically isolated from the input signal tare Tares display to 0 Of...

Страница 29: ...one This feature is available in Easy and Advanced Modes Display shows defs n Defaults no Press the DOWN button to change the display to defs y Defaults Yes if you want to return to default conditions...

Страница 30: ...econds Set1 Set2 Output Alarms Digit OK Max Min Reset Display shows FIL XX X where XX X is the time constant in seconds Use the UP or DOWN button to increase or decrease this value Default FIl 00 0 Se...

Страница 31: ...is less than 10 per con version Guidance For noisy systems increase the Filter Jump value up to a maximumof 99 Choose a value which gives a good compromise between filtering and response speed For re...

Страница 32: ...d up to the nearest 1 no rounding 2 5 10 20 or 50 Lockout Switch must be OFF Press 3 seconds Set1 Set2 Output Alarms Digit OK Max Min Reset Press repeatedly until you see LSt X where X is either 1 2 5...

Страница 33: ...vitational acceleration is reduced to 9 782m s2 You can correct for this difference by setting Scale 9 812 9 782 1 003 so that a given mass in Bangkok will show the same weight as it did in London Set...

Страница 34: ...2 Output Alarms Digit OK Max Min Reset Press repeatedly until you see OFFSEt followed by the existing offset value Default is 000 000 1 2 3 4 Set1 Set2 Output Alarms Digit OK Max Min Reset Use DIGIT b...

Страница 35: ...OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press repeatedly until you see dLAY XX where XX is the delay in seconds Choices are dLAy 1 0 dLAy 20 dLAy 30 dLAy 60 default 1...

Страница 36: ...put Alarms Digit OK Max Min Reset Press OK button briefly and repeatedly until you see rEV d 0 Default or rEV d 1 Set1 Set2 Output Alarms Digit OK Max Min Reset Press briefly to toggle 1 2 3 4 Set1 Se...

Страница 37: ...utton is pressed Lockout Switch must be OFF Press together briefly Set1 Set2 Output Alarms Digit OK Max Min Reset Press OK button briefly and repeatedly until you see boot 0 or boot 1 or boot 2 or boo...

Страница 38: ...n 4 Press the Up arrow to change display to defs Y and press OK 5 If you want all channels to share a common setting eg calibration do that setting now 6 When you want to do separate settings for eac...

Страница 39: ...more than this the resistor has probably been overloaded and burned by having a voltage connected across it Please check your field wiring to en sure that no more than 30mA or 1V can be applied to the...

Страница 40: ...n in the diagram If the meter doesn t yet have an output option board the top screw may not yet be fitted 4 Slide the electronic boards out throught the front of the case You can easily separate the u...

Страница 41: ...o dispose of it It must not be thrown away with general rubbish If you are unable to dispose of this item locally you may send it to us for recycling Conditions 1 We will only accept items of our manu...

Страница 42: ...co 25 ppm Degree Celsius Zero Tempco 30 ppm Degree Celsius 24V Excitation voltage 24VDC nominal rated at 60mA 10V Excitation voltage 10VDC nominal rated at 20mA Filtering smoothing Selectable time con...

Страница 43: ...tect this board If a previous version board is installed the meter will skip switched capacitor filter section of menu The newly released 9122 2470 input board allows selection of 5V or 10V excitation...

Страница 44: ...be routed separately to power carrying cabling includes relay output wiring All signal cabling shall be screened The screen shall only be terminated to the power earth terminal at the meter end of th...

Отзывы: