Vestil DJG-100 Скачать руководство пользователя страница 2

rev. 5/5/2017 

   DJG-100, MANUAL 

Copyright 2017 Vestil Manufacturing Corp.                                                               Page 2 of 14 

 

Signal Words  

 

This manual uses SIGNAL WORDS to direct the reader’s attention to statements about uses of the 

product that could result in personal injury or property damage. Each signal word connotes a specific 
hazard level. The following are definitions of signal words that might appear in this manual. 

 

   

 

 

Identifies a hazardous situation which, if not avoided, WILL result in DEATH or 
SERIOUS INJURY.  Use of this signal word is limited to the most extreme 
situations. 

 

 

Identifies a hazardous situation which, if not avoided, COULD result in DEATH or 
SERIOUS INJURY. 

 

 

Indicates a hazardous situation which, if not avoided, COULD result in MINOR or 
MODERATE injury. 

 

                              Identifies  practices  likely  to  result  in  product/property  damage,  such  as  operation  that 

might damage the product.

 

 

 

 

 
 

Hazards of Improper Use: 

 Improper or careless use might result in serious personal injury. 

 

Read and understand the entire manual before assembling, installing, using or servicing this product.

 

 DO NOT attempt to resolve any problem(s) with the product unless you are both authorized to do so and 

certain

 that it 

will be safe to use afterwards. 

 DO NOT modify the product in any way without first obtaining written approval from Vestil. Unauthorized modifications 

automatically void the Limited Warranty (p. 14) and might make the product unsafe to use. 

 This barricade should only be used to direct vehicular traffic. It is not a guardrail.  

 Do not apply any weight to the barricade arm, particularly as the barricade is opened. Do not hold onto the arm while 

it rises.  

 Inspect the product as recommended in the “Inspections and Maintenance” section on p. 12. Do not use the product 

unless it is in normal condition. 

 DO NOT use this barricade UNLESS all labels are present, easily readable (not significantly faded), and undamaged. 

(See “Labeling Diagram” on p. 13). 

 
 

 Proper maintenance is essential for this product to remain in normal, working condition. 

o

  Periodically lubricate pivot points. 

o

  Do not use brake fluid or jack oils in the hydraulic system.  If oil is needed, use an anti-wear hydraulic oil with a 

viscosity grade of 150 SUS at 100°F, (ISO 32 cSt @ 40°C), or Dexron transmission fluid. 

 

 
 

 

 

 
 
 

 

 

 
 
 
 
 

 

 
 
 
 

 
 

 

 

 

 

Содержание DJG-100

Страница 1: ...nd maintenance comply with laws regulations codes and mandatory standards applied where the product is used Vestil Manufacturing Corp 2999 North Wayne Street P O Box 507 Angola IN 46703 Telephone 260...

Страница 2: ...using or servicing this product DO NOT attempt to resolve any problem s with the product unless you are both authorized to do so and certain that it will be safe to use afterwards DO NOT modify the p...

Страница 3: ...ead cutting screw slotted type F zinc plated 5 16 18x3 4 1 22 23 112 002 Pin hinge 1 8 01 118 001 Bolt cylinder retaining 1 23 99 051 021 Black yellow safety tape 114 2 9 23 514 018 Weldment arm rest...

Страница 4: ...ad cutting screw slotted type F zinc plated 5 16 18x3 4 1 22 23 112 002 Pin hinge 1 8 01 118 001 Bolt cylinder retaining 1 23 99 051 023 Black yellow safety tape 114 2 9 23 514 018 Weldment arm rest 1...

Страница 5: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 5 of 14 Electrical Layout 115V 1 Phase with Sensor 23 124 001 Rev H...

Страница 6: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 6 of 14 Electrical Circuit Diagram 115V 1 phase with sensor 23 124 001 Rev H...

Страница 7: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 7 of 14 Electrical Layout 208 230V 1 Phase with Sensor 23 124 002 Rev G...

Страница 8: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 8 of 14 Electrical Circuit Diagram 208 230V 1 Phase with Sensor 23 124 002 Rev G...

Страница 9: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 9 of 14 Electrical Layout 460V 3 Phase with Sensor 23 124 003 Rev G...

Страница 10: ...rev 5 5 2017 DJG 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 10 of 14 Electrical Circuit Diagram 460V 3 Phase with Sensor 23 124 003 Rev G...

Страница 11: ...ations of both models DJG 100 and DJG 100 10 Install 3 4 anchor bolts of appropriate length determined by your building engineer through the bolt holes in the base plate and arm rest to secure the uni...

Страница 12: ...t how the unit looks and sounds as the arm raises and lowers This written record establishes normal condition When conducting future inspections compare those observations with the written record to d...

Страница 13: ...G 100 MANUAL Copyright 2017 Vestil Manufacturing Corp Page 13 of 14 Labeling diagram A C B D E F F A B Label 221 C Label 248 251 matched to line voltage A Label 208 D Label 287 E Label 206 F Label 204...

Страница 14: ...n the following original dynamic components motors hydraulic pumps electronic controllers switches and cylinders It also covers defects in original parts that wear under normal usage conditions wearin...

Отзывы: