17
An approved suitable cable must be connected from the Consumer Unit (main fuse
box) and be protected by its own 30amp fuse or Micro Circuit Breaker (MCB). The
electrician must provide a fused double-pole switch, which disconnects both the line
(live) and neutral conductors with a contact seperation of at least 3,0 mm.
The fused switch should be fitted to the kitchen wall, above the worksurface and to
the side of the hob, not above it, in accordance with IEE regulations. Connect the
fused switch to a junction box which should be fitted on the wall about 61cm (24
inches) above floor level and behind the hob. The hobs power supply cable can then
Making an electrical connection
Before making a connection, check that:
·
The mains voltage is the same as that quoted on the rating plate which is situated
at the back of your hob.
·
The circuit can support the appliance load (see the rating plate).
·
The power supply has an earth connection, which complies with the provisions of
current regulations and is in good working order.
·
The fused switch is easily accessible once the hob has been installed.
If there is no dedicated hob circuit and fused switch, they must be installed by a
qualified electrician before the hob is connected.