English - 8
GSM / WIFI GENERAL CONTROLS
To display the IMEI number on EVC models with GSM Modules,
press “GSM IMEI“ button.
To display the MAC address on EVC models with WIFI modules,
press “WIFI MAC“ button.
To reset the GSM module on EVC models with GSM modules,
press “GSM RESET“ button.
To display the Signal Quality, press “Signal Quality“ button. The
signal quality display may be ON/OFF.
In this mode EV charger only measures signal level and prints
it on terminal screen. Signal quality mode must be disabled to
connect the EV charger to an OCCP central system.
If your EVC models is EVC02-AC*U** and supports cellular connectivity, you should check GSM signal quality
level before the installation of the unit. Switch to “GSM / WIFI“ page from menu and click the “Signal Quality”
icon (If your SIM card has PIN code, you need to configure PIN code first from “Connectivity Settings“ page).
EV charger will change its operation mode to GSM signal measurement. The signal level will be printed on the
terminal screen continously. GSM / 3G connection quality will vary based on the operator grid coverage area.
The device direction and placement must be completed where the signal quality is best.
•
If the signal quality is between 0-14, the signal is not powerful enough to establish connection.
•
If the signal quality is between 14-22, the signal is at medium level and you can configure your charging
station.
•
If the signal quality is between 22-31, the signal is at high level.
After checking signal quality, click the “Signal Quality” button again to shutdown signal quality check mode and
switch the EVC to the normal operation mode. New cellular connectivity settings must be completed for proper
operation. Switch to the “Connectivity Settings“ page from menu.