      Adjustment manual

1. Temperature Sensor Comparative Voltage Adjustment

Measurement Point 

TP-4 (VC) TP-I(GND)

Adjusting Point

:

R351 (470ohm Cermet Trimmer

Measurement Equipment

DC Millivoltmeter (input impedance I00K ohm )

   

Setting Conditions    

:  

Power on.  Turntable stopped.

   Adjustment Sequence :

(1)

 Power on.

(2)

 Connect DC Millivoltmeter to TP-4.

(3)

 Adjust R351 to give 1,540mV± 5mV.

2. Center Frequency of Pitch Control Adjustment
  

Measurement Point            :

TP-3 (CP) TP-I(GND)

Adjusting Point

:

L501 (3.3mil OSC Coil)

Measurement Equipment

:

Frequency Counter

Setting Conditions

:

Power on.- Turntable stopped.  Quartz Lock o-ff.

Adjustment Sequence:

  (1)

Power on.

  (2)

Connect Frequency Counter to TP-3-

                                        (3)

Pitch control fader center position.

  (4)

Adjust L501 for Frequency Counter 230.4KIlz ±0.IKHz.

3.  Meter Sensitivity adjustment.

Measurement Point

:

Check meter needle deflection.

Adjusting Point

:

R506 (4.7Kohm Cermet Trimmer)

Measurement Equipment: :

N/A

Setting Conditions

:

Power on. Turntable stopped. Quartz Lock off.

Adjustment Sequence:

 (1)

Power on.

 (2)

Quartz Lock off.

 (3)

Set Pitch control fader to @10% position.

 (4)

Adjust R506 so that meter shows +10%.

 (5)

Set Pitch control fader to -10% position.

 (6)

Recheck points so that -10% and +10% are in correct
position.

4.  APC Offset Adjustment

Measurement Point

:

TP-2 (APC) TP-1(GND)

Adjusting Point

:

R308 (47Kohm Cermet Trimmer)

Measurement Equipment

:

DC Millivoltmeter (input impedance 100Kohm.)

Setting Condition

:

Power on. Turntable 33 1/3rpm. Quartz Lock on.

Adjustment Sequence:

 (1)

Power on.

 (2)

Quartz Lock on, Speed 33 1/3 rpm, Start.

   (3)    Adjust R308 so that DC Millivoltmeter shows

3.5volt±0.2volt.

   (4)      Set Pitch control fader to -10% position.

NOTE; Rotate R308 slowly to allow correct voltage to set.