Lux sensor in Vestamatic Radio System (VRS).
G
85400521 H1
For inside mounting on the window pane
Transmit commands combined with Touch Control VRS
– Contact a professional electrician to install the control system.
– Check the control system for signs of mechanical damage af
ter unpacking. If you notice any shipping damage, do not start
up the control system and notify your supplier immediately.
– The control system should only be used for the purpose spec
ified by the manufacturer (refer to the operating instructions).
Any changes or modifications thereof are not permissible and
will result in loss of all warranty claims.
– If the control units or the connected sunshade cannot be oper
ated without presenting a hazard, it must be switched off and
prevented from being switched on unintentionally.
– This device contains a pollutant battery. The end user must re
cycle all used batteries in accordance with regulation 91/157/
EWG. Disposing of the batteries in household waste is strictly
forbidden.
Radio frequency:
868 MHz
Modulation: FSK
Power supply:
1 × 3 VBattery, CR 2032
Protection degree:
IP 50
Programmable range:
2 kLux to 60 kLux
Operating temperature:
0°C (32°F) to +70°C (158°F)
Range in buildings:
approx. 30 m
Dimensions (L × W × H):
Ø 41 × 13 mm
Weight:
13 g
Conformity:
p
This product conforms to the basic requirements of the R&TTE Directive
1999/5/EC. The Declaration of Conformity can be found on the web page:
www.vestamatic.com.
The Lux sensor can only be used in connection with Vestamatic controls for
the wireless transmission of control commands.
The manufacturer will not assume any liability for damage caused by im
proper or inappropriate handling.
The Lux sensor periodically measures the current brightness value. If the
brightness exceeds or falls below the userdefined threshold, the sensor
transmits a movement command to the control.
If the brightness value is over the threshold for one minute, the
DOWN
command is transmitted. If the brightness value is below the threshold for
16 minutes, the
UP
command is transmitted.
1. Stick the adhesive ring on the outside of the transparent casing.
ACHTUNG!
Verdecken Sie den
Sensor nicht.
2. Stick the sensor close to the bottom edge of the window onto the cleaned
window glass from the inside.
Note:
For removing the sensor can simply be taken off the window
pane. Rub off the remainder of adhesive with your fingers before
you stick on a new adhesive ring.
1.
Fit batteries
Open the casing and insert the battery into the compartment.
ATTENTION!
The positive pole
must be visible.
2.
Setting the threshold.
To set the threshold at which the sensor is to respond, wait until the
current brightness is appropriate. Then push the sensor button (> 3 sec
onds) until the LED lights up. The current brightness value is saved as
the new threshold.
If you wish to change the threshold, repeat the procedure – the old value
is overwritten.