DIP switch SW1:
S1 S2 S3 S4
Operating
mode
Tilting
*
No. Application
OFF OFF OFF OFF 1
standard
venetian
blinds
/
curtain
blinds
OFF OFF OFF ON 2
venetian blinds /
curtain
blinds
with slow start velocity
OFF OFF ON OFF 3
roller
shutters
OFF OFF ON ON 4 IDS venetian bl./curtain bl. adjustable,
with autom. interlock
0 – 2 s
OFF ON OFF OFF 5 IDS spec. venetian blinds/ adjustable,
curtain blinds
0 – 5 s
special
function
1
OFF ON OFF ON 6 IDS spec. venetian blinds/ adjustable,
curtain blinds
0 – 2 s
special
function
2
OFF
ON
ON OFF 7
roller shutters
no tilting
possible
OFF ON ON ON 8 venetian
blinds
without
slow
start
velocity
ON OFF OFF OFF 9
IDS venetian blinds / adjustable,
curtain blinds
0 – 2 s
4
h
locking
ON OFF OFF ON 10 IDS venetian blinds / adjustable,
curtain blinds
0 – 2 s
4
h
locking
possible
only via
central
command
possible
only via
central
command
possible
only via
central
command
possible
only via
central
command
Tilting time
Depending on the operating mode selected one of the following tables shall apply for setting the
required tilting time. The tilting time will only be executed after a central command!
Tilting time table for operating mode 5
Tilting time table f. operating mode 4, 6, 9, 10
* This is where you can note your project-specific basic settings.
DIP switch SW 2:
S1
S2
S3
S4
Tilting time
*
OFF OFF OFF OFF no
tilting
OFF OFF OFF ON
0.1 s
OFF OFF ON OFF
0.2
s
OFF OFF ON
ON
0.3 s
OFF
ON OFF OFF
0.4 s
OFF ON OFF ON
0.5
s
OFF
ON
ON OFF
0.6 s
OFF ON ON ON
0.7
s
ON OFF OFF OFF
0.8
s
ON
OFF OFF ON
0.9 s
ON OFF ON OFF
1.0
s
ON
OFF ON
ON
1.2 s
ON
ON OFF OFF
1.4 s
ON ON OFF ON
1.6
s
ON
ON
ON OFF
1.8 s
ON ON ON ON
2.0
s
DIP switch SW 2:
S1
S2
S3
S4
Tilting time
*
OFF OFF OFF OFF no
tilting
OFF OFF OFF ON
0.4 s
OFF OFF ON OFF
0.7
s
OFF OFF ON
ON
1.0 s
OFF
ON OFF OFF
1.3 s
OFF ON OFF ON
1.6
s
OFF
ON
ON OFF
1.9 s
OFF ON ON ON
2.2
s
ON OFF OFF OFF
2.5
s
ON
OFF OFF ON
2.8 s
ON OFF ON OFF
3.1
s
ON
OFF ON
ON
3.4 s
ON
ON OFF OFF
3.7 s
ON ON OFF ON
4.0
s
ON
ON
ON OFF
4.5 s
ON ON ON ON
5.0
s
DIP switch SW 3:
S1 S2 S3 S4 Run
time
*
OFF OFF OFF OFF
5
s
OFF OFF OFF ON
10 s
OFF OFF ON OFF
15
s
OFF OFF ON
ON
18 s
OFF
ON OFF OFF
21 s
OFF ON OFF ON
24
s
OFF
ON
ON OFF
27 s
OFF ON ON ON
30
s
ON OFF OFF OFF
35
s
ON OFF OFF ON
40 s
ON OFF ON OFF
50 s
ON OFF ON ON
60 s
ON ON OFF OFF
80 s
ON ON OFF ON
100 s
ON ON ON OFF 120 s
ON ON ON ON 180 s
The duration of the retract command is always 180 s.