background image

Subject to modifications.

© Vestamatic GmbH

Art.-Nr.: 

8600 001 GB 4416 A00  •  Vestamatic GmbH  •  Dohrweg 27  •  D-41066 Mönchengladbach 

 •  www.vestamatic.com

MC P4 LoVo / VRS

1/4

G

MC P4 LoVo

MC P4 LoVo VRS

Art.-no.:

01077420 / 01077417

Installation and Operating Instructions

MC P4 LoVo

 

Art.-no.: 01077420

MC P4 LoVo VRS

 

Art.-no.: 01077417

Programmable motor controls for operating 4 sunshade devices
with group and individual controls, either wire-bound or
via 868 MHz radio link.

Technical data

Short description

Assembly and installation

  Microprocessor-powered motor controller for four sunshade controls
  Standard 3-wire central input
  Direct connection available for four Lovoline SMI / ME motors or 24VDC motors
  Connection available for group button
  Connection available for four individual buttons
  Separate connection terminals for mains supply and central transmission
  10 different operating modes can be set, incl. inching mode and intelligent 

decentralised operation

  Motor run time/tilting time can be individually set
  Control via VRS radio remote control or VRS wall-mounted radio transmitter 

(MC P4 LoVo VRS)

Notes for professional electricians

1.  Switch off the power supply.
2.  Undo the housing cover screws and lift off the housing cover.
3.  Use the four mounting holes at the edges of the housing to mount it.
4.  Connect the power supply cables and external connections ac cord ing to the wiring

diagram. Do not lay cables above or below the PC board.

5.  Set the desired operating mode.
6.  Set the desired motor run time and the tilting time, if necessary.
7.  Switch on the power supply.
8.  Check the motor’s direction of rotation and correct it, if necessary.
9.  Replace the housing cover and tighten the housing cover screws.

Safety precautions

 – Contact a professional electrician to install the control system.
  –  Check the control system for signs of mechanical damage after un-

packing. If you notice any shipping damage, do not start up the control 

system and notify your supplier immediately.

 

–  The control system should only be used for the purpose specified by 

the manufacturer (refer to the operating instructions). Any changes or 

modifications thereof are not permissible and will result in loss of all 

warranty claims.

 

–  If the control unit cannot be operated without presenting a hazard, it must

be switched off and prevented from being switched on unintentionally.

 – 

When performing work on the windows, controls or connected shades, 

protect them against unauthorised or unintentional operation.

Ä

WARNING!
Risk of injury due to improper installation and commissioning.

Improper installation and commissioning may lead to personal injury or 

property damage.
Therefore:

 

–  When connecting the device, observe the currently valid VDE standards

(in particular DIN VDE 0100/0700), your local power company’s regula-

tions and the current accident prevention regulations.

 

–  Connect the control in accordance with the wiring diagram.

 

–  Only use central control with floating contact output.

Ä

Accessories

  Control for creating sub-groups (GC 3-)

The product meets the essential requirements of R & TTE  Directive 1999 / 5 / EC. The 

declaration of conformity is available on the following website: 

www.vestamatic.com

Conformity

G

1/4

G

Wiring diagram – for connecting Lovoline SMI/ME motors

 ATTENTION! 

(Notice applies for all displayed wiring diagrams)

 

Only use central control with  floating contact output.

Ä

Power supply: 

22 – 28VDC

Radio frequency (MC P4 LoVo VRS): 

868 MHz

Fuse: 

T 4A

Total permissible motor current: 

max. 2A

Operating temperature: 

0 °C (32 °F) to +40 °C (104 °F)

IP class: 

IP 54

Conformity:

 

p

Dimensions (L × W × H): 

170 × 134 × 85 mm

Output: 24VDC
 Align switching time extend: 

3 – 180 s

 Align switching time retract: 

180 s

 IMPORTANT!

 

When using Lovoline SMI / ME motors, DIP S4 is set as follows:

  1 = ON; 2 = OFF.

Ä