Vestal Vestal Aire 9 Скачать руководство пользователя страница 4

Installation Instructions for VESTAL Circulator Fireplace 

 

General:

 The mason is urged to read these instructions carefully. Frequent reference to these instructions and drawings will help the 

mason to do a perfect job of installing the Circulator Unit. Particular attention should be given to the application of the glass wool 
insulation. The Circulator Unit must not be used as a support for the masonry. The masonry at all points must be self

supporting. 

Keep masonry 1/2” to 1” away from the steel at all points to allow for normal heat expansion. See that any mortar squeezed from the 
mortar joints does not touch the unit at any point. 
 

Foundation

: Foundation dimensions will vary with the size of the Circulator used–type of masonry (brick or stone)–number and 

size of any other flues in the same chimney–and width of fireplace on each side of the fireplace opening. Therefore, due to the 
unlimited variety of applications for the Vestal Circulator Fireplace Unit, it is impossible to give specific details that cover all 
installations and dimensions of the foundation. 
The foundation is to be constructed of concrete or solid masonry and generally should be at least 12” thick and extend beyond the 
masonry walls 6” on all sides unless codes or conditions call for greater thickness and/or extension. 

 
UNIT SIZES 

Finished Opening 

Model No. 

Width Height 

Fuel Capacity 

Shipping Weight 

30 

28” 

24” 

Up to 24” 

195 

34 

32” 

26” 

Up to 28” 

237 

38 

36” 

28” 

Up to 32” 

275 

42 

40” 

28” 

Up to 36” 

335 

50 

48” 

28” 

Up to 42” 

420 

 

 

 
UNIT DIMENSIONS IN INCHES 

MODEL  

A B C D E F G H  I  J K L 

30 

30 

34 

221/4 

18 1/2 

34 

30 

46 1/4 

15 1/4 

14 

25 

11 3/4 

7 3/4 

34 

34 

38 

24 1/4 

19 3/4 

38 

32 

49 3/4 

16 1/2 

14 

27 

11 1/2 

11 1/2 

38 

38 

42 

28 1/4 

21 1/4 

42 

35 

53 3/4 

17 1/2 

16 

29 1/4 

11 1/2 

11 1/2 

42 

42 

47 

31 1/4 

23 1/4 

47 

38 

58 1/4 

19 1/4 

16 

32 

16 1/2 

11 1/2 

50 

50 

56 

39 1/4 

25 1/4 

56 

40 1/4 

62 3/4 

20 1/4 

17 

34 

16 1/2 

11 1/2 

 

CHIMNEY FLUE SIZES 

FOR CHIMNEYS OVER 20’ HIGH 

FOR CHIMNEYS 16’ TO 20’ HIGH 

MODEL  

NO. 

STANDARD 

FLUE 

MODULAR  

FLUE 

ROUND  

FLUE 

STANDARD 

FLUE 

MODULAR 

FLUE 

ROUND 

FLUE 

30 

8 1/2” x 13” 

12” x 12” 

10” 

8 1/2” x 13” 

12” x 12” 

10” 

34 

8 1/2” x 13” 

12” x 12” 

10” 

13” x 13” 

12” x 16” 

12” 

38 

13” x 13” 

12” x 16” 

12” 

13” x 13” 

12” x 16” 

12” 

42 

13” x 13” 

12” x 16” 

12” 

13” x 18” 

16” x 16” 

15” 

50 

13” x 18” 

16” x 16” 

15” 

13” x 18” 

16” x 20” 

15” 

Outside dimensions shown for standard and modular flues — inside dimensions for round flues. Chimney height is measured from hearth. 
 

NOTE: Dimensions shown are actual measurements. Be sure to allow 1/2” to 1” space for glass wool insulation for heat expansion 
between all points of the Circulator and the masonry. 