REMINDER:   

Batteries are considered HAZARDOUS WASTE and must be disposed of properly.   

Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by local 

regulations.

 

 

TECHNICAL SPECIFICATIONS 

 

Model 

 

VP600 

VP1000 

VP2000 

Capacity    (VA/W) 

600/300 

1000/600 

1920/1200 

Input 

 

 

 

 

Voltage Range 

82~148Vac 

Frequency 

50/60Hz(Auto Sensing) 

Output 

 

 

 

 

On Battery Output 
Voltage 

Simulated Sine Wave at /-10% 

On Battery Output 

Frequency   

50/60 Hz +/-1Hz 

Overload Protection 

Breaker/Internal Current Limiting 

Physical 

 

 

 

 

Outlets-total 

Outlets-Battery & 

Surge Protected 

Outlets-Surge Only 
Protected 

Dimensions(W X H X 

D)mm 

96 X 138 X 286 

148 X 178 X 298 

Weight (kg) 

4.35 

8.66 

11.36 

Battery 

 

 

 

 

Sealed Maintenance 

Free Lead Acid 

Battery 

12V/7AH*1 

12V/7AH*2 

12V/9AH*2 

Typical Recharge 
Time 

4 Hours to 90% capacity 

Warning Diagnostics 

Indicators 

Power On, UPS Status Display, Capacity Display, Digital Value Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Environmental 

 

 

 

 

Operating 

Temperature 

0

C to 40

C   

Operating Relative 

Humidity 

0 to 90% 

Communication 

 

 

 

 

Power Guide 

Windows 10/ Windows 8/ Windows 7/ Windows Server 2012 R2/ Windows 

Server 2008 R2,linux,Mac

 

Management 

 

 

 

 

Auto-Charger 

Yes 

Auto-Restart 

Yes 

USB 

Yes 

RJ45/11 

Communication 
Protection Ports 

Yes 

 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

 

LCD Indication 

 

 

 

 

 

 

 

 

 

Setting Item 

 

 

 

 

 

 

 

Line mode 

 

Bat-mode 

 

 

 

Fault 

 

Sound disable 

(Press the display key 

3s to disable and enable 

the buzzer sound) 

 

 

 

Bat mode: battery capacity 

Line mode:   

1. Battery charging: cycle 

lighting 

2. Battery full charged: 

lighting 

3. Line mode without 

charger: battery capacity 

 

Load capacity 

 

Line mode & BATT. Mode 
 

 

 

 

Initial 

AC INPUT(Voltage) 

 

OUTPUT(Voltage) 

 

 

TROUBLE SHOOTING

 

 

Problem 

Possible Cause 

Solution 

The UPS does 

not perform 

expected 

runtime. 

Batteries are not fully charged. 

Recharge the battery by leaving the UPS 

plugged in. 

Battery is slightly worn out. 

Contact Technical Support. 

The UPS will not 

turn on. 

 

The on/off switch is designed 

to prevent damage by rapidly 

turning it off and on. 

Turn the UPS off. Wait 10 seconds and then 

turn the UPS on. 

The unit is not connected to an 

AC outlet. 

The unit must be connected to a 120Vac 

50/60Hz outlet.     

The battery is worn out. 

Contact Technical Support. 

Mechanical problem. 

Contact Technical Support.   

Outlets do not 

provide power to 

equipment 

Circuit breaker is tripped due 

to overload 

Turn the UPS off and unplug at least one 

piece connected equipment. Unplug the 

power cord of the UPS then press the circuit 

breaker knob. 

Batteries are discharged 

Allow the unit to recharge for at least 4 

hours. 

Unit has been damaged by a 

surge or spike. 

Contact Technical Support.   

Power Guide is 

inactive 

The serial/USB cable is not 

connected. 

Connect the serial/USB cable to the UPS 

unit and an open serial port on the back of 

the computer. You must use the cable that 

came with the unit. 

The unit is not providing 

battery power. 

Shutdown your computer and turn the UPS 

off. Wait 10 seconds and turn the UPS back 

on. This should reset the unit. 

 

FCC COMPLIANCE STATEMENT 

 

FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation. 

Note

: This equipment has been tested and found to comply with part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the 

following measures: 

- Reorient or relocate the receiving antenna. 

- Increase the separation between the equipment and receiver. 

- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.  

- Consult the dealer or an experienced radio/TV technician for help. 

Important

: Changes or modifications not expressly approved by the party responsible for compliance 

could void the user's authority to operate the equipment.

 

Canadian Compliance 

CAN ICES-3 (B)/NMB-3(B) 

 

SOFTWARE DOWNLOAD 

 

Power Guide management software provides a user-friendly interface for your power systems.   

The graphic user-interface is intuitive and displays essential power information at a glance.   

Please follow procedure below to install the software. 

Installation procedure: 

Download Power Guide from the website:   

http://www.powermonitor.software/ 

Double-click the file and follow the installation steps. 

When your computer restarts, the Power Guide software 

  will appear as a blue icon located in the system tray. 

 

 

 

All rights reserved. Reproduction without permission is prohibited. 

 

 