Features 

 

Battery and Low Battery Detection 

The IR Remote Control uses two 1.5V Lithium batteries as its power source. It features Low Battery 
Detection function. When low battery voltage is detected, the IR Remote Control will transmit Low Battery 
signal to the coordinator in ZigBee network. 

 

Supervision 

The 

IR Remote Control will transmit a supervision signal to report its condition regularly according to user 

setting. The factory default interval is 30 minutes. The user can also press the ZigBee Button once to 
transmit a supervision signal manually. 
 

ZigBee Network Setup 

 

ZigBee Device Guideline 

The IR Remote Control is a wireless communication protocol that is reliable and has low power consumption 
and high transmission efficiency. Based on the IEEE802.15.4 standard, ZigBee allows a large amount of 
devices to be included in a network and coordinated for data exchange and signal transmission. 
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after 
powering on. Since performing a task in connecting network may consume some power, it is required to 
follow the instructions to avoid draining battery of a ZigBee device. 
- Ensure the ZigBee network router/coordinator is powered on before inserting battery into ZigBee device. 
- Ensure the ZigBee network router/coordinator is powered on and in range while ZigBee device is in use. 
- Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery 

from a ZigBee device. 

 

Joining the ZigBee Network 

As a ZigBee device, the IR Remote Control needs to join a ZigBee network to receive command from 
ZigBee network coordinator to transmit IR signal. Please follow the steps bellow to join the IR Remote 
Control into the ZigBee network. 

The IR Remote Control can only join ZigBee network within 3 minutes after power on. 

1.  Insert batteries to power on the IR Remote Control. 
2. 

Within 3 minutes

, press and hold the ZigBee button for 10 seconds, then release it to join the network. 

Please make sure the permit-join feature on the router or coordinator of your ZigBee network is enabled. 

3.  After joining the ZigBee network, the IR Remote Control will be registered in the security system in the 

network automatically. Please check the security system control panel or CIE (Control and Indicating 
Equipment) to confirm if joining and registration is successful.   

4.  If the IR Remote Control successfully joins the ZigBee network, the ZigBee LED will flash twice to 

indicate. 

5.  After joining the ZigBee network, if the IR Remote Control loses connection to current ZigBee network, 

the ZigBee LED indicator will flash every 20 minutes. Please check the ZigBee network condition and 
the IR Remote Control signal range to correct the situation. 

 

Removing Device from ZigBee Network (Factory Reset) 

To remove the device from current ZigBee network, the IR Remote Control must be put to Factory Reset to 
complete device removal. Factory Reset function will clear the IR Remote Control of its stored setting 
information and prompt the device to search for new ZigBee network.   

Before removing device, make sure the device is within current ZigBee network signal range 

1.  Delete the IR Remote Control from current control panel / CIE. 
2.  The device can only be reset 

within 3 minutes

 after power up. If the IR Remote Control has been 

powered up for more than 3 minutes, remove and reinsert the battery. 

3.  Press and hold the function button for 10 seconds, then release the button to reset device. 
4.  Upon reset, the IR Remote Control will clear current ZigBee network setting and transmit signal to 

ZigBee coordinator to remove itself from current ZigBee network. It will then actively search for available 
ZigBee network again and join the network automatically.   

 

 

 

 

 

 

 

 

Содержание UPIC-5 ZBS

Страница 1: ...smits IR signal to appliances 2 ZigBee Button 3 IR Button 4 ZigBee LED Flashes twice IR Remote Control successfully joins ZigBee network Flashes every 20 minutes IR Remote Control has lost connection to its current ZigBee network 5 IR Indicator LED Slow Flash IR Remote Control under IR learning mode Quick Flash IR Remote Control receives IR signal under learning mode or is transmitting IR signal F...

Страница 2: ... Remote Control can only join ZigBee network within 3 minutes after power on 1 Insert batteries to power on the IR Remote Control 2 Within 3 minutes press and hold the ZigBee button for 10 seconds then release it to join the network Please make sure the permit join feature on the router or coordinator of your ZigBee network is enabled 3 After joining the ZigBee network the IR Remote Control will b...

Страница 3: ...thers Fan X means the location of this switch has no effect on appliance selection Example a To select Air Conditioner slide Switch 1 to ON and Switch 2 6 to OFF b To select Television slide Switch 2 to ON and Switch 3 6 to OFF ignore Switch 1 position Step 3 Learn IR Data Each appliance type can learn up to 8 IR signals selected with Dip Switch Set 2 Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 S...

Страница 4: ...Switch 3 Switch 4 Switch 5 Switch 6 Appliance Selection ON OFF OFF OFF OFF OFF Type 1 Air Conditioner OFF ON OFF OFF OFF OFF Type 2 Television OFF OFF ON OFF OFF OFF Type 3 Home Audio OFF OFF OFF ON OFF OFF Type 4 Set Top Box OFF OFF OFF OFF ON OFF Type 5 Others Fan Slide more than one switch to ON will select multiple appliance type Example a Slide Switch 1 2 3 4 5 to ON will select all 5 applian...

Страница 5: ... Remote Control to send IR signal 1 learnt in Air Conditioner appliance type IR Signal Coverage IR LED Selection The IR Eye of the IR Remote Control includes 6 LEDs which are used to transmit IR signals with 1 central LED and 5 surrounding LEDs The 5 surrounding LEDs are positioned at 45 angle to the PCB board LED Signal Coverage Each LED transmits IR signal in cone coverage in front of the LED Th...

Страница 6: ...on Power Use the jumper switches JP2 and JP3 to adjust the IR signal transmission power Factory default is set to Low transmission power JP1 ON Setting the jumper to JP2 will increase the IR signal transmission range ...

Страница 7: ...ng 0 32 bytes Read Write O 0x0011 PhysicalEnvironment 8 bit 0x00 0xff Read Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Power CFG Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0035 BatteryAlarmMask map8 0b0000 000x Read Write 0x00 0 Attribute of Identify Cluster Information Identifier Name Type Range Access Default Mandator...

Страница 8: ...isable For example 20 100000 in Bit number meaning that only LED 6 The central LED will be activated when UPIC transmit IR signal in this appliance type If you want to set the IR signal to be transmitted with both LED 2 and LED 6 the value in bit number will be 0010 0010 0x22 0 0 1 0 0 0 1 0 Reserved Reserved LED 6 Enable LED 5 Disable LED 4 Disable LED 3 Disable LED 2 Enable LED 1 Disable 0010 00...

Отзывы: