ZigBee Network Setup 

 

 

ZigBee Device Guideline 

ZigBee  is  a  wireless  communication  protocol  that  is  reliable  and  has  low  power  consumption  and  high  transmission 
efficiency.  Based  on  IEEE802.15.4 standard,  ZigBee  allows  a  large amount  of devices  to  be  included  in  a  network  and 
coordinated for data exchange and signal transmission. 

Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. 
Since performing a task in connecting network may consume some power, it is required to follow the instructions to avoid 
draining battery of a ZigBee device. 

Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device. 

Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use. 

Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a 
ZigBee device. 

 

 

Joining the ZigBee Network 

As a ZigBee device, the Sensor needs to join a ZigBee network to transmit signal when it is triggered. Please follow the 
steps bellow to join the Sensor into the ZigBee network. 

1.  Remove the insulator from the Sensor to power on. 
2.  After powering up, use sharp tools such as a paper clip to press and

 

hold the Function button for 10 seconds until LED 

flash once, then release it to join the network. Please make sure the permit-join feature on the router or coordinator of 
your ZigBee network is enabled. 

3.  If the Sensor successfully joins a ZigBee network, the LED Indicator will flash twice to confirm (refer to you Control 

Panel to complete learning). 

4.  After joining the ZigBee network, the Sensor will be registered in the network automatically. Please check the ZigBee 

coordinator, system control panel  or  CIE  (Control  and  Indicating  Equipment)  to  confirm if  joining  and  registration is 
successful. 

5.  After joining the ZigBee network, if the Sensor loses connection to current ZigBee network, the LED will flash every 20 

minutes to indicate. Please check your ZigBee network condition and Sensor signal range to correct the situation. 

 

Removing Device from ZigBee Network (Factory Reset) 

To remove the Sensor from current ZigBee network, the Sensor must be put to Factory Reset to complete device removal. 
Factory Reset function will clear the Sensor of its stored setting and information and prompt the Sensor to search for new 
ZigBee network.   

Before removing device, make sure the Sensor is within current ZigBee network signal range 

1.  Press and hold the function button for 10 seconds, then release the button to reset Sensor. 
2.  Upon reset, the Sensor will clear current ZigBee network setting and transmit signal to ZigBee coordinator to remove 

itself from current ZigBee network. It will then actively search for available ZigBee network again and join the network 
automatically.   

 

Installation 

The Sensor should be installed on a glass to detect shock/vibration or glass breakage. Use the double side adhesive tape 
provided to secure the Sensor on the window. 

 

Appendix 

(For developers only)

 

 

Vibration Movement Sensor Cluster ID 

Device ID: IAS Zone 0x402 
Endpoint: 0x01 
Server Side 

Client  Side 

Mandatory 

Basic (0x0000) 

Basic (0x0000)

 

Identify(0x0003) 

 

IAS Zone(0x0500) 

 

Optional 

None 

None 

 

Attribute of Basic Cluster Information 

Identifier 

Name 

Type 

Range 

Access 

Default 

Mandatory / 

Optional 

0x0000 

ZCLVersion 

Unsigned 8-bit 

integer 

0x00 –0xff 

Read only 

0x01 

Содержание SVGS-1ZBS

Страница 1: ...ttery and Low Battery Detection The Sensor use one CR2032 3V Lithium battery as its power source Please note ALWAYS replace battery with the correct size and voltage The Sensor can detect if the battery is low When the Battery is low a low battery signal will be sent to the Control Panel along with regular transmission When changing battery use a sharp tool to open the battery slot to remove and i...

Страница 2: ...l to complete learning 4 After joining the ZigBee network the Sensor will be registered in the network automatically Please check the ZigBee coordinator system control panel or CIE Control and Indicating Equipment to confirm if joining and registration is successful 5 After joining the ZigBee network if the Sensor loses connection to current ZigBee network the LED will flash every 20 minutes to in...

Страница 3: ...rite 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Identify Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 IdentifyTime Unsigned 16 bit integer 0x00 0xffff Read Write 0x0000 M Attribute of IAS Zone Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0001 ZoneState 8 bit Enumeration All Read only ...

Страница 4: ...is connected Consult the dealer or an experienced radio TV technician for help FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices FCC Radiation Exposure Statement Th...

Отзывы: