Installation 

 

 

Wiring 

WARNING 

Wiring of the device should only be performed by a licensed electrician. The circuit box’s main breaker 
should be turned off to perform installation.   

 

The insertion hole wire specification is AWG18 or Ø 1.02 (mm

²

). 

 

The Clamp specification is 60A Ø10mm 

 

Please make sure the main power in your facility is also off before installing. Follow the steps below: 
1. Connect AC Input cable to a socket near the Electrical Box to power on the Clamp Meter. 
2. Open the clamp as indicated by below picture. The clamp should be applied onto an electric cable The 

arrow direction on the clamp need to point at the correct direction of the electricity current flows (

K

L

). If 

arrow is faced in reverse direction, the reading will display negative value (-) however it will not influence 
the readings. 

         

         

 

 

3. Follow the schematics below as an example;  clip the clamps on the electricity cables on the 2 the 

incoming power cable connected to the Main Circuit Breaker. 

 

 

 

Mounting 

The Clamp Meter has a mounting bracket for mounting purposes. 

1. Use the mounting bracket as template to mark the two holes on the wall for installing screws. 
2. Screw the mounting bracket onto the wall according to marked location. Install wall plugs if necessary. 
3. Locate the hooks of the mounting bracket and line up the hooks with the mounting holes on the Clamp 

Meter. Fit the hooks into the mounting holes as picture below. Installation is now complete. 

 

Содержание CLMT-1ZW

Страница 1: ...can be routed to their destination via intermediary listening Z Wave products Parts Identification 1 Red LED Flashes once When Clamp Meter is transmitting a signal Flash Twice The Clamp Meter has successfully joined a Z Wave network 2 AC Input cable 3 Current Transformer Cable CT2 4 Current Transformer Cable CT1 5 Function Button Press the button once to report the value of the meter to the Z Wave...

Страница 2: ...t at the correct direction of the electricity current flows K L If arrow is faced in reverse direction the reading will display negative value however it will not influence the readings 3 Follow the schematics below as an example clip the clamps on the electricity cables on the 2 the incoming power cable connected to the Main Circuit Breaker Mounting The Clamp Meter has a mounting bracket for moun...

Страница 3: ...e if the Z Wave Gateway or Control Panel is lost or otherwise inoperable Press and hold the Function Button of the device for 10 seconds to factory reset Range Test To test whether the device is able to communicate with the Z Wave Gateway or Control Panel Put the Gateway Control Panel into range test mode Walk Test Press the Function Button on the device The Gateway Control Panel should display if...

Страница 4: ...tion KWh read from CT1 Group 3 for meter CT2 maximum node 1 Meter CC V2 For group 3 the Switch will report 1 The sum of instant Power Consumption Watt read from CT2 2 The sum of accumulated Power Consumption KWh read from CT2 Z Wave s Multi Channel Association The Multi Channel Association Command Class is used to create application bindings to Multi Channel End Point resources as well as to Root ...

Страница 5: ... Channel Association CC V3 Meter CC V2 Descirption For Endpoint 1 the Clamp Meter will report 1 Instant Power Consumption Watt read from CT1 2 Accumulated Power Consumption KWh read from CT1 Selected Endpoint 2 for CT2 of the second channel Device Type Simple Meter Supported Command Classes Z Wave Plus info CC V2 Association CC V2 Association Group Information CC Multi Channel Association CC V3 Me...

Отзывы: