18
Fault
Cause
Resolution
Black Glass
Wet Fuel
Season Wood foe at least 12-18
Months.
Low Flue Pressure
Consult Installer
Damaged Rope Seal
Fit new rope seal
Blocked Flue
Consult chimney sweep/Installer
Fire goes out
Wet wood,
Season Wood foe at least 12-18
Months.
Low Flue Pressure
Consult installer, this could be due
to downdraught or you may require
a liner
Blocked Flue
Consult chimney sweep.
No combustion Air
Fit combustion air brick in line with
document J of Building regulations
Cant slow
down burn
rate
Damaged rope seal
Replace rope seal using HT Silicone
Door Handle Loose
Adjust collar tension using allen key
Flue Blanking Plate Loose
Realign flue blanking plate and seal
all joints with fire cement.
Firebricks
cracking after
1-6 months
Wet fuel, careless loading
Ensure fuel is dry. Do not load fuel
by throwing into the fire
Paint blister-
ing
Fire cement contact, burning too
hot.
Rub down back to bear metal using
wire wool or 240 grit sand paper
then re-coat using Thermacure HT
paint.