9
Installation
Compressed air piping
CAUTION
Remember
Be sure to use an air hose with sufficient pressure resistance performance. A
hose without pressure resistance could burst or leak air.
Compressed air used
This unit requires that clean compressed air be supplied
for the dust removal air blowing.
Supply air within the pressure range of 0.1 to 0.5 MPa.
Use an air drier to remove the moisture from the air. (The
dew point temperature is -15°C or lower.)
Use mist separator (0.3
µ
m) to remove the impurities from the air.
Supply air within the temperature range of 5 to 40 °C
Hose used
Use an air hose with sufficient pressure resistance performance
(outside diameter 10 mm x inside diameter 6.5 mm).
Hose connection
A one-touch hose coupling (air supply port) is provided on the lower left at the back of the body.
Connect the air hose to this.
Flow rate adjustment
A flow rate adjusting valve (FLOW CONTROL) is provided on the lower right
at the front of the body. Adjust the rate of the discharged air as necessary.
Flange
A paper pack filter can be attached to the exhaust port on
the rear side (standard).
A ø75mm (I/D) exhaust duct can be connected by
exchanging it for a duct flange.
Pre-use inspection
Pre-use product inspection
Before using the product, make sure there are no
problems with it, the power adapter, etc. Make sure there
is no damage, and no loose of screws or connectors.
Содержание IPC-A3
Страница 6: ...6 外観図 外観図 ...
Страница 26: ...6 External View ...
Страница 46: ...6 External View ...
Страница 66: ...6 External View ...
Страница 86: ...6 External View ...
Страница 106: ...6 External View ...
Страница 126: ...6 External View ...
Страница 146: ...6 External View ...
Страница 166: ...6 External View ...