26
TM30 User Manual v. X1.0
Power consumption
9...80mA, average 55mA
Rated voltage
AC: 400Vrms, DC: 600V
Output connectors
2 pcs 4mm safety banana sockets
Output fuse
200mA, fast, 600V
Over voltage class
EN 61010-1 CAT III 600V
Enclosure
ABS, 155 x 90 x 50mm
Weight
Approx. 460g (with batteries)
Enclosure protection rating IEC 60529 IP55
Storage conditions
-30...+60C, dry conditions
Usage conditions
-20...+40C, dry or damp conditions
Receiver
TMR30
Receiving frequencies
Trace modes: modulated 125kHz
Monitor modes:
Powerline: 50Hz (<200Hz)
Audio freq: <10kHz
High freq: >10kHz
Adjustments
3-level gain adjustment
Connectors
None
Indicators
12-level LED bar display for receiving signal strength, 9 other
LEDs, internal speaker for trace signal and indication tones
Batteries
4pcs. 1.5V IEC LR03 alkaline batteries (or similar NiMH cells),
max. battery voltage 6.5V, low bat warning at approx. 4.5V
Power consumption
16...100mA, average 30mA
Enclosure
ABS, 180 x 61 x 50mm
Weight
Approx. 250g (with batteries)
Enclosure protection rating IEC 60529 IP34
Storage conditions
-40...+60C, dry conditions
Usage conditions
-40...+60C, dry or damp conditions
8.2. Maintenance, storage and warranty
TM30
cable and wire tracer does not have any parts that require maintenance by the
user, excluding changing of batteries (see paragraph 3.1). A damaged device must be
returned to the manufacturer for repair. A soiled device can be cleaned using a damp
cloth and it must be dried carefully before returning it to the carrier bag. We recommend
that the device is stored in its own carrier bag under dry conditions and at room
temperature. If device becomes immersed in water, batteries must be immediately
removed and the battery compartment lid left open in order to allow for the device to
dry. The device is left to dry at room temperature.
H.Vesala Oy (Ltd.) shall not accept liability of any financial losses or damages, nor for
any damage incurred to people, the environment, telecommunications traffic or similar as
a result of the use of or the failure to use the device.
TM30
has a one-year warranty against factory defects. Warranty shall not cover
batteries or faults resulting from normal wear and tear or misuse. Users are advised to
contact the manufacturer in case of faults or queries relating to the use of the device.
The product has been designed and manufactured in Finland. VESALA
®
is a registered
trademark of H.Vesala Oy (Ltd.).
Содержание TraceMeter TM30
Страница 1: ...Cable Wire Tracer TraceMeter TM30 User manual v X1 0 ...
Страница 2: ...1 TM30 User Manual v X1 0 ...