![VESALA PK2 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/vesala/pk2/pk2_user-manual_1008723007.webp)
7 (22)
User Manual Vesala PK2 Receiver X2.0 ENG
Performance in free air, room temperature,
≥1000 mm from conductive objects
Lateral error: ±3% of actual distance
between units
Distance error: ± 1 cm ± 10%
Operating frequency band,
maximum power transmitted
9000…13350 Hz, input
83.000…83.666 kHz, < 10 mW
433.47…434.37 MHz, input
Electromagnetic environment
ETSI EN 301 489-1: Residential, commercial
and light industrial environment
Receiver category
2
International standards this product is in
conformance with
EN 300 220-1
EN 300 220-2
EN 300 330
EN 301 489-1
EN 301 489-3
EN 303 454