IMPORTANT
Before attempting to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes after electrical disconnection before
attempting access. This will allow any moving parts to come to a rest.
VES Andover Ltd Eagle Close Chandlers Ford Ind. Est Eastleigh Hampshire SO53 4NF
Tel: 08448 15 60 60 Fax: 02380 261204 e-mail: [email protected] web: www.ves.co.uk
Original Instructions : Installation, Operation & Maintenance Manual
Original Instructions : Installation, Operation & Maintenance Manual
WEEE Directive
At the end of their useful life the packaging and product should
be disposed of via a suitable recycling centre. Do not dispose of
with normal household waste. Do not burn.
Standards
VENA fans conform to all relevant British and European
standards and directives. Further information is available
from VES Andover Ltd on request
Please ensure that this document is passed on to the end user
We reserve the right to alter the specification without notice
©VES Andover Ltd. 2010. No part of this publication may be
photocopied or otherwise reproduced without the prior
permission in writing of VES Andover Ltd.
Wiring Diagrams
Maintenance
1. Before cleaning, isolate the fan completely from the mains supply.
2. Carefully remove the front cover
3. To clean the front cover, either wipe it with a damp, lint free cloth or
wash it in warm soapy water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts
of the fan.
5. Never use strong solvents to clean the fan.
6. Apart from cleaning, no other maintenance is required.
For replacement fans or install kits please visit
www.vesdirect.co.uk
Specification
Power Supply
230VAC 50Hz
Operating Temperature
0~40°C
Insulation Class
1
Motor Protection
IPX2
Motor Type
Ball bearing
Speed (rpm)
1420
Power (W) (240/290)
30/50
Current (A) (240/290)
0.13/0.16
Warranty
The fan is guaranteed against defects for 1 year from the date of purchase.
If you have any problems, contact VES at the address shown below.
Using the fan chasis as a
template, mark centre holes
on mounting surface
Remove the front cover
from the fan by hand - tools
not required
Original Instructions : Installation, Operation & Maintenance Manual
Wire the fan as per
wiring diagram &
instructions
Prepare a hole in mounting
surface for the fan spigot &
plug mounting holes as
required
Carefully replace the
front fan cover
Installation
continued
Secure fan backing
plate to mounting
surface
Standard Wiring
(Typical Installation)
IMPORTANT
All electrical work should be carried out by a qualified engineer and in
accordance with the current IEE Regulations.
Before attempting to carry out any maintenance or repair work on our
units, the unit MUST BE COMPLETELY ISOLATED from its electrical supply.
Ensure a minimum of two minutes after electrical disconnection before
attempting access. This will allow any moving parts to come to a rest.
Fuse
Double Pole
Isolating Switch
L
N
E
Fan
Terminals
Not Used
Not Used
L
N
E
Remove terminal cover
retaining fixings
Make the connection as per the
wiring diagram as above. Replace the
terminal cover.
IMPORTANT
The fan must be fused at 3A unless it forms part of a 5A lighting circuit.
An isolator should be installed to isolate all poles to the fan.