IMPORTANT SAFETY INSTRUCTIONS 

General Safety 

 

DANGER!  

YOU MUST FOLLOW APPROVED SAFETY PROCEDURES. 

Performing the following procedures may expose you to hazards.  These procedures should be 
performed by qualified technicians familiar with the hazards associated with this type of equipment.  
These hazards may include shock, energy, and/or burns.  To avoid these hazards: 

a)

 

The tasks should be performed in the order indicated. 

b)

 

Remove watches, rings, and other metal objects. 

c)

 

Prior to contacting any uninsulated surface or termination, use a voltmeter to verify that no voltage 
or the expected voltage is present.  Check for voltage with both AC and DC voltmeters prior to 
making contact. 

d)

 

Wear eye protection. 

e)

 

Use certified and well maintained insulated tools.  Use double insulated tools appropriately rated for 
the work to be performed. 

 

Personal Protective Equipment (PPE) 

 

DANGER!  

ARC FLASH AND SHOCK HAZARD. 

Appropriate PPE and tools required when working on this equipment.  An appropriate flash protection 
boundary analysis should be done determine the “hazard/risk” category, and to select proper PPE. 

 

This product is intended only for installation in a Restricted Access Location. 

 

Only authorized and properly trained personnel should be allowed to install, inspect, operate, or maintain 
the equipment. 

 

Do not work on LIVE parts.  If required to work or operate live parts, obtain appropriate Energized Work 
Permits as required by the local authority, per NFPA 70E “Standard for Electrical Safety in the 
Workplace”. 

 

Handling Equipment Containing Static Sensitive Components 

 

ALERT!  

Installation or removal of equipment containing static sensitive components requires careful 

handling.  Before handling any equipment containing static sensitive components, read and follow the 
instructions contained on the Static Warning Page. 

Содержание SM-TEMP

Страница 1: ...NetSure SM TEMP Temperature Concentrator Installation and User Manual UM547490 Revision N Specification Number 547490...

Страница 2: ...fically described in this document The products covered by this instruction manual are manufactured and or sold by Vertiv This document is the property of Vertiv and contains confidential and propriet...

Страница 3: ...PE 5 Handling Equipment Containing Static Sensitive Components 5 Static Warning 6 Description 7 Specifications 7 Electrical 7 Environmental 7 Accessories 8 Dimensions 10 Installation 11 Important Safe...

Страница 4: ...if not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable standards OSH...

Страница 5: ...double insulated tools appropriately rated for the work to be performed Personal Protective Equipment PPE DANGER ARC FLASH AND SHOCK HAZARD Appropriate PPE and tools required when working on this equ...

Страница 6: ...s necessary Read and follow wrist strap manufacturer s instructions outlining use of a specific wrist strap 3 Do not touch traces or components on equipment containing static sensitive components Hand...

Страница 7: ...rently on the same CAN bus The SM TEMP module provides an analog output of the average or the maximum DIP switch configurable of the temperatures of the connected sensors The output is a current sourc...

Страница 8: ...he output voltage of the system to maintain battery float current as battery temperature decreases or increases respectively Battery life can be extended when an optimum charge voltage to the battery...

Страница 9: ...Vertiv NetSure SM TEMP Temperature Concentrator Installation User Manual UM547490 Rev N 9 Figure 1 Temperature Probe Kit...

Страница 10: ...NetSure SM TEMP Temperature Concentrator Installation User Manual UM547490 Rev N 10 Dimensions Figure 2 Dimensions in inches 0 34 3 18 TOP VIEW 5 31 0 23 FRONT VIEW BOTTOM VIEW REAR VIEW RIGHT SIDE VI...

Страница 11: ...ion of switch S1 Table 1 S1 Output Mode Switch Settings POSITION FUNCTION 1 Compensation Mode for SM TEMP Analog Output Maximum Average Temperature 2 CAN Address switch position 2 sets the most signif...

Страница 12: ...NetSure SM TEMP Temperature Concentrator Installation User Manual UM547490 Rev N 12 Figure 3 Connector Locations S1 Rear View TB1 TB2 TB3 TB4 Analog Output Cable 0 MAX AVG MSB LSB ADDRESS S1 1 2 3 4 1...

Страница 13: ...A 6 DIN rail P N 116765 is included with each module Mounting the Battery Temperature Probes DANGER Batteries can produce large amounts of electrical current Read and follow the Important Safety Inst...

Страница 14: ...U or SCU when the SM TEMP is not present The temperature probes plug into the eight connectors on the top row on the back of the SM TEMP P1 P8 Temperature probe connections are made by means of lockin...

Страница 15: ...M NO BATTERY NO ALARM BATTERY ALARM JUMPER NC COM NO NC COM NO BATTERY NO ALARM BATTERY ALARM JUMPER NC COM NO GROUND NO ALARM GROUND ALARM NC COM NO GROUND NO ALARM GROUND ALARM JUMPER NC COM NO BATT...

Страница 16: ...unit when using the analog output of the SM TEMP The analog output connections are made to TB1 pins 1 2 Refer to Figure 3 and Figure 5 When multiple SM TEMP modules are used the analog output of only...

Страница 17: ...TEMP module to an ACU or NCU temperature port input the SM TEMP module can simply be connected at the end of the ACU or NCU CAN bus The analog output connections ARE NOT REQUIRED CAN bus connections...

Страница 18: ...Rev N 18 Connecting the SM TEMP Module s CAN Terminals to the NCU or ACU CAN Bus in a Spec No 582136800 Power System List 5 List8 Refer to Figure 7 Figure 7 SM TEMP Connections when connecting the SM...

Страница 19: ...open temperature probes will be permanently lost d If the STATUS LED flashes green CAN address switches 2 4 on two SM TEMP units connected by single CAN bus are set to the same address Changing the s...

Страница 20: ...at at least one temperature probe is connected to the SM TEMP STATUS LED illuminates GREEN Normal operation is indicated Table 3 Status Indicators TYPE COLOR DESCRIPTION LED Green Module is powered an...

Страница 21: ...tch and the address switches no adjustment of the SM TEMP is required or provided Refer to the Power System documentation for all Power System adjustment procedures TROUBLESHOOTING AND REPAIR NOTE Ref...

Страница 22: ...are trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracy and completeness here Vertiv Group Corp assumes no responsibili...

Отзывы: