background image

 

 

Vertiv

 

|

 

eSure™ Power Extend Converter Mounting Bracket and Door Kit Installation Manual (IM60017372)

 

|

 

Rev. C 

Personal Protective Equipment (PPE) 

 

DANGER!  

ARC FLASH AND SHOCK HAZARD. 

Appropriate PPE and tools required when working on this equipment.  An appropriate flash protection 
boundary analysis should be done to determine the “hazard/risk” category, and to select proper PPE. 

 

Only authorized and properly trained personnel should be allowed to install, inspect, operate, or maintain 
the equipment. 

 

Do not work on LIVE parts.  If required to work or operate live parts, obtain appropriate Energized Work 
Permits as required by the local authority, per NFPA 70E “Standard for Electrical Safety in the 
Workplace”. 

Hazardous Voltage 

 

DANGER!  

HAZARD OF ELECTRICAL SHOCK. 

More than one disconnect may be required to de-energize the system before servicing. 

Handling Equipment Containing Static Sensitive Components 

 

ALERT!  

Installation or removal of equipment containing static sensitive components requires careful 

handling.  Before handling any equipment containing static sensitive components, read and follow the 
instructions contained on the Static Warning Page. 

 

STATIC WARNING 

 

This equipment contains static sensitive components.  The warnings listed below must be observed to 
prevent damage to these components.  Disregarding any of these warnings may result in personal injury 
or damage to the equipment. 

1.

 

Strictly adhere to the procedures provided in this document. 

2.

 

Before touching any equipment containing static sensitive components, discharge all static 
electricity from yourself by wearing a wrist strap grounded through a one megohm resistor.  Some 
wrist straps have a built-in one megohm resistor; no external resistor is necessary.  Read and follow 
wrist strap manufacturer’s instructions outlining use of a specific wrist strap. 

3.

 

Do not touch traces or components on equipment containing static sensitive components.  Handle 
equipment containing static sensitive components only by the edges that do not have connector 
pads. 

4.

 

After removing equipment containing static sensitive components, place the equipment only on 
static dissipative surfaces such as conductive foam or ESD bag.  Do not use ordinary Styrofoam or 
ordinary plastic. 

5.

 

Store and ship equipment containing static sensitive components only in static shielding containers. 

6.

 

If necessary to repair equipment containing static sensitive components, wear an appropriately 
grounded wrist strap, work on a conductive surface, use a grounded soldering iron, and use 
grounded test equipment. 

Содержание eSure 60017372

Страница 1: ...eSure Power Extend Converter Mounting Bracket and Door Kit Installation Manual IM60017372 Revision C Kit Specification Number 60017372...

Страница 2: ...thorization from Vertiv Group Corp is strictly prohibited 2020 Vertiv Group Corp All rights reserved Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp All other n...

Страница 3: ...ing Equipment Containing Static Sensitive Components 6 Static Warning 6 eSure Power Extend Converter Mounting Bracket and Door Kit Installation Instructions 7 Kit Description 7 Tools and Material Requ...

Страница 4: ...e injury if not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable stand...

Страница 5: ...ld be performed in the order indicated b Remove watches rings and other metal objects c Prior to contacting any uninsulated surface or termination use a voltmeter to verify that no voltage or the expe...

Страница 6: ...ipment contains static sensitive components The warnings listed below must be observed to prevent damage to these components Disregarding any of these warnings may result in personal injury or damage...

Страница 7: ...ield install an eSure Power Extend Converter using one of the kits listed in Table 1 Installation of this kit in other systems not listed in Table 1 should not be attempted Table 1 Power System Mounti...

Страница 8: ...asher factory assembled to side brackets 4 233362700 6 32 x 3 8 Screw 4 are factory assembled to side brackets 8 60016951 Front Mounting Bracket 1 152175 Hot Surface Label factory assembled to front b...

Страница 9: ...te that it was read Important Safety Instructions DANGER Adhere to the Important Safety Instructions starting on page 5 and those listed in the power system manual CAUTION When performing any step in...

Страница 10: ...ent the kit supplied left side mounting bracket as shown in Figure 2 Secure to distribution panel with kit supplied hardware as shown in Figure 2 Torque hardware as indicated in Figure 2 Figure 2 Inst...

Страница 11: ...nt mounting bracket as shown in Figure 3 Secure the front mounting bracket to the left side mounting bracket as shown in Figure 3 DO NOT TIGHTEN HARDWARE hardware will be tightened during power extend...

Страница 12: ...ibution panel with kit supplied hardware as shown in Figure 4 Torque hardware as indicated in Figure 4 Secure the front mounting bracket to the right side mounting bracket as shown in Figure 4 DO NOT...

Страница 13: ...en installing a power extend converter mounting bracket kit covered by these instructions onto a stand alone distribution cabinet installed in an outside plant enclosure leave the front door off the s...

Страница 14: ...ribution panel as a guide record the distribution positions onto the kit supplied label 10 Place the kit supplied distribution position label see Figure 7 back into the kit supplied storage pouch or r...

Страница 15: ...Kit P N 566026 12 Continue with the Installing the Power Extend Converter into a Distribution Position procedure starting on page 16 Distribution Position Label Toggle Breaker Guard Kit P N 566026 Ex...

Страница 16: ...els pertain to the average output power busy hour average power drawn by the load including any power loss in the cable The peak power available from each unit remains at 1000 watts regardless of spac...

Страница 17: ...reaker and verify the load and return cables for the position are wired and labeled correctly At the same time connect the power extend converter return wire faston tab P N 565990 provided with the po...

Страница 18: ...60016097 Load Lead Lug 1 4 Flat Washer 1 4 Lock Washer Torque to 72 in lbs 1 4 20 x 5 8 Bolt Load Lead Lug 1 4 Lock Washer 1 4 20 x 5 8 Bolt Torque to 72 in lbs 1 4 Flat Washer Load Return Lead Lug 1...

Страница 19: ...re jumper P N 565752 may be installed with the P N 564330 return wire if additional return wire length is preferred NOTE The power extend converter is also furnished with an 8 inch long return wire ju...

Страница 20: ...Converter Power Extend Converter Return Wire P N 564330 Power Extend Converter Return Wire Faston Tab P N 565990 Power Extend Converter Power Extend Converter Orient the white square on the return wir...

Страница 21: ...epeat for each power extend converter to be installed 5 Secure the power extend converter s to the mounting bracket with the screw provided with the power extend converter Torque as shown in Figure 13...

Страница 22: ...Observe the status of the power extend converter front panel local indicator If operating normally this indicator should be illuminated green See Figure 12 on page 21 9 Close and secure the door 10 En...

Страница 23: ...Vertiv eSure Power Extend Converter Mounting Bracket and Door Kit Installation Manual IM60017372 Rev C 23 This page is intentionally blank...

Страница 24: ...Vertiv com Vertiv Headquarters 1050 Dearborn Drive Columbus OH 43085 USA IM60017372 RC 06 2020...

Отзывы: