Do one of the following:
Q
If the board does not pass POST.
Reseat or replace the board and run DCM
again. If it still fails, contact your Technical Support representative.
Q
If the board passes POST.
Go to the next step.
The diagnostic settings in the following table indicate that a DM3 board has passed
POST:
2.
To verify whether Windows is able to detect the board and IRQ, run PCITree, a utility
that lists installed PCI boards. PCITree may show boards that do not appear in
Windows Device Manager.
You can download PCITree from the following location:
http://www.pcitree.de/
Intel Dialogic PCI boards are identified by one of the following Vendor IDs (VID):
Q
10b5 PLX Technology.
Identifies a DM3 board.
Q
12C7 Dialogic Corp.
Identifies a non-DM3 board.
To display the VID for a board, click on the board in the PCITree main window. The
VID is displayed in the PCI Device pane at the upper right of the PCITree window.
Model number
Type
LED settings after successful POST
DM/IPx
IP telephony board
All lights are off.
DI/SI32
Station board
2 yellow lights are blinking, green and red lights are
solid on.
DISI/xR2
Station board
HDSI/x
Station board
All lights are off.
DM/V160LP,
DM/V160LPEU
Analog trunk board
DM/V2400A
Conference bridge board
Green light stays on.
DI0408LSAR2
Integrated trunk and station
board
Содержание TeleVantage 7.5
Страница 1: ...INSTALLING INTEL TELEPHONY COMPONENTS TELEVANTAGE 7 5 ...
Страница 2: ......
Страница 4: ......
Страница 14: ......
Страница 15: ...Section 1 Preparing for Installation ...
Страница 16: ......
Страница 30: ......
Страница 31: ...Section 2 Installing Intel HMP ...
Страница 32: ......
Страница 50: ......
Страница 51: ...Section 3 Installing Intel Boards and Drivers ...
Страница 52: ......
Страница 72: ......
Страница 116: ......
Страница 117: ...Appendixes ...
Страница 118: ......
Страница 126: ......
Страница 154: ......
Страница 174: ......
Страница 180: ......