T1 Maintenance (continued)
T1 CLEAR ERROR
This tool allows you to clear any errors (i.e., for Hour Count only) that have been registered as described in “T1
Error Threshold” on page 110 and “T1 Error Seconds Totals” on page 111. After using the Clear T1 Error tool, the
contents (errors) will automatically be sent to the KSU. The KSU will then clear the T1 Error Count for the specified
error.
NOTE
You can clear specific errors or ALL errors. The default for this screen is for ALL options to be
checked.
IMPORTANT!
Contact Vertical Technical Support for assistance with understanding and clearing errors.
1) Go to Maintenance
X
T1 Maintenance
X
Clear Errors to display the Clear Error screen.
2) Select any or all of the errors you want to clear.
• The default is to clear ALL registered errors.
3) Click Clear T1 Error to clear the selected errors.
4) Click OK to close the Send succeed window.