– 16 –
7.0 Options
Options/Accessories to the cooler are described below.
7.1 UV Stage
An additional stage after the filters is available for all models. The UV stage pro-
vides a UV light which disinfects the water. This option is installed at the factory as
an additional stage of the filter system. The UV light must be replaced once per year.
7.2 Automatic Sanitization Module
This module generates ozone from the air and dispenses the ozone into the
water tank periodically on a time cycle to sanitize the system. T
h
is option (OZ) is
also installed at the factory.
7.3 Filter Backpacks for Models 500/600 and 1000RF
These models do not have space for built-in filtration and require a supply of
filtered water. The backpack filter option (FP) attaches to the back of the cooler and
will take tap water and filter it. Reverse Osmosis is not available in this option. It is
installed at the factory.
8.0 Filter Replacement
The filter elements must be replaced at regular intervals to maintain the quality of the water.
The 1000F, 1010F, 2000F and 3000F versions have 2-stages of mechanical filtration.
A 1st stage 5-micron sediment filter and a 2nd stage activated carbon filter. The filter ele-
ments in both stages must be replaced every 6-12 months.
The 1000R, 1010R, 2000R and 3000R models have the 2-stages of mechanical filtration
plus an additional Reverse Osmosis membrane element. The 2 pre-filters must be replaced
every 6-12 months. The Reverse Osmosis membrane must be replaced every 3 years.
8.1 Replacement Procedures, Filtration Versions (F) 1000, 2000 and 3000 Coolers
a) Remove the lower front panel of the 2000 or 3000 cooler (swing open the
front hinged cover on 1000 models.
b) Close the ball valve to stop water flow through the filters.
c) Place a pan under the filters to catch water. The filters will have water in them
which will run out when the tubing connections are broken.
d) Disconnect tubing–inlet and outlet for each of the 2-filters.
e) These filters are disposable, encapsulated filters. Remove and discard entire
filter body. Replacement filters are:
1st Stage sediment filter
P/N IFA-4035
2nd Stage carbon filter
P/N IFA-4034