Vertex PWC-1000 Скачать руководство пользователя страница 1

VERTEX

Water Products

PureWaterCooler

Water Dispenser

OWNERS INSTALLATION

MANUAL

VERTEX WATER PRODUCTS 

Models

PWC3000/2000/600

3 Temp - Room, Hot, Cold

PWC1000/1010/500

2 Temp - Hot, Cold

Montclair, CA - USA

Содержание PWC-1000

Страница 1: ...VERTEX Water Products PureWaterCooler Water Dispenser OWNERS INSTALLATION MANUAL VERTEX WATER PRODUCTS Models PWC3000 2000 600 3 Temp Room Hot Cold PWC1000 1010 500 2 Temp Hot Cold Montclair CA USA ...

Страница 2: ...f valve accessory be installed as well Vertex P N LC 8021 2 Water supply connection to coolers are to be made with the flexible plastic tubing provided If connecting a hard copper line to cooler connection the Bulkhead fitting on back of cooler must be replaced with a proper metal fitting 3 Do not position the cooler where it can be hit or bumped by Vacum cleaners or floor waxing machines This can...

Страница 3: ...ng pg 19 11 0 Specifications pg 20 12 0 Warranty pg 21 List of Figures Figure 1 Assembly Drawing Model PWC 2000 and PWC 3000 pg 4 Figure 2 Flow Schematic pg 5 Figure 3 Filter Schematic pg 5 Figure 4 Installation Precautions pg 6 Figure 5 Water Connections pg 7 Figure 6 Drain Connections for RO filter pg 8 Figure 7 Quick Connect Fittings pg 9 Figure 8 Model 1000 Assembly pg 12 Figure 9 Water Connec...

Страница 4: ...cron filter and a 50 gal lon per day RO membrane The filters remove sediment and dirt and the taste and odor of chlorine and other contaminants The reverse osmosis stage removes mole cular contaminants from the water The R version requires a drain line connection to the drain trap to remove rejected water to the sewer The F version has the sediment and carbon filters but not the RO membrane theref...

Страница 5: ...from the mounting Inspect filter system to see that nothing is damaged or dis lodged from shipping 3 0 Description Model 2000 and 3000 3 1 Description The assembly drawing is shown in Figure 1 The Model 2000 3000 PureWaterCooler has 3 tanks There is a main holding water tank with float valve mech anism which controls a solenoid valve on the water feed line to maintain a constant level of filtered ...

Страница 6: ...er is converted into good tasting clean safe drinking water 4 Figure 1 Assembly Drawing PWC 2000 PWC 3000 COVER SNAP ON TOP COVER STEAM EXHAUST COVER HOT WATER TANK COVER HOT WATER TANK MAIN WATER TANK COVER MAIN WATER TANK CONTROL PANEL MAIN OUTLET TUBE COLD WATER RELEASE LEVER ROOM WATER RELEASE LEVER HOT WATER RELEASE LEVER CUP BASE SNAP ON FRONT PANEL RELEASE BUTTONS WATER LEVEL INDICATOR CONT...

Страница 7: ...0 Vent Float Type Water Level Control Main Water Tank Cold Tank Electric Heating Coil Inside Tank Check Valve Drain Water Spigots Purified Water Inlet from filters Hot Room Cold Figure 3 Filtration Schematic Front of cooler with panel removed ...

Страница 8: ... or kitchen sink Flexible 1 4 inch plastic tubing may be used for the feed and discharge connections Normally these connections should be with in 25 feet of the cooler 6 Do not touch STEAM HOLE or open HOT WATER TANK COVER while dispenser is in use Model 2000 Be sure to use correct power volt age plug dispenser s power plug directly into electrical socket Figure 4 Installation Precautions Provide ...

Страница 9: ...tions must be removed before making water connections To remove the tube sections see figure 7 Disconnect The 1 4 plastic tubing should be used for making the Feed Water and Drain connections If hard copper tubbing is used for the Feed Water and Drain con nections the bulkhead fittings must be changed to a metal fitting Figure 5 Back View of Cooler Water Connections ...

Страница 10: ...be hooked to the drain line ahead of the normal sink water trap See Figure 6 below Place the 2 part drain saddle on the drain pipe before the drain trap Allow proper space for the drilling operation Tighten the saddle bolts evenly on both sides Using the opening in the drain outlet saddle as a guide drill a 1 4 hole in the drain pipe Clean any debris out of the drain saddle connection Connect the ...

Страница 11: ...ushed into the tube stop Push the tube into the fitting to the tube stop The collet gripper has stain less steel teeth which hold the tube firmly in position while the O ring pro vides a permanent leak proof seal Pull on the tube to check it is secure It is good practice to test the system prior to leaving site and or before use To disconnect ensure the system is depressurized before removing fitt...

Страница 12: ...PureWaterCooler Pull the cover off exposing the main tank cover Remove this cover to expose the inside of the main tank Plug in the power cord to115 volt wall socket to activate the solenoid shut off valve you should hear an audible click CAUTION DO NOT PUSH ANY HOT OR COLD POWER CONTROLS ON YET Water will flow into the main tank and then the cold and hot tanks as well Let cool er tanks fill with ...

Страница 13: ...essed to dispense hot water 4 5 Dispensing To obtain hot warm or cold water place cup or glass onto cup base directly under desired water type Press down release lever for water to flow until cup or glass is full 4 6 Hot Water Function To activate hot water press the HOT POWER button CAUTION MAKE SURE THERE IS WATER IN THE HOT TANK AND IT CAN BE DISPENSED FROM THE FAUCET BEFORE TURNING ON HOT POWE...

Страница 14: ...everse osmosis R or standard filter F versions 5 2 Position Cooler Same procedure as for Model 2000 see3 2 5 3 Water Connections Fig 9 shows the back of the 1000 cooler which has the same water connec tions as the 2000 Model Note that there are separate hot and cold power switches to turn on for operation There is no front control panel in the 1000 model There are three LED indicators which includ...

Страница 15: ... ballvalve inside the cooler 1 4 turn handle in line with tube is on Check all connections to assure there are no leaks CAUTION DO NOT TURN ON HOT OR COLD POWER CON TROLS YET Remove the top cover of the PureWaterCooler by removing 2 screws from back of top cover Pull the cover off exposing the main tank The 1000 1010 unit use a mechanical float valve to control flow to the tank The unit does not h...

Страница 16: ...ks fill again with the filtered water When full drain water again through the drain ports located on the back as well as through the dis pensing spigots When the tank has filled again automatically with filtered water the cooler is ready to dispense water Figure 10 Front of Model 1000 cooler with door opened Auto Shut off Valve ...

Страница 17: ...In Section 3 0 It does not have space for the filter package there fore purified water must be supplied to it An optional filter for the back of the unit can be ordered as noted above 6 3 Model 1000RF This is a free standing hot and cold Model 1000 2 temperature cooler as described before but with a 0 5 cubic foot refrigerator in the bottom of the cabinet The refriger ator replaces the space in wh...

Страница 18: ...tervals to maintain the quality of the water The 1000F 1010F 2000F and 3000F versions have 2 stages of mechanical filtration A 1st stage 5 micron sediment filter and a 2nd stage activated carbon filter The filter ele ments in both stages must be replaced every 6 12 months The 1000R 1010R 2000R and 3000R models have the 2 stages of mechanical filtration plus an additional Reverse Osmosis membrane e...

Страница 19: ...of pliers remove the RO element from the housing by grasping the tube end and pulling it out e Use RO filter replacement P N ma 4203 50gpd TFC membrane Insert the element into the housing with double o ring end going in first toward the bottom of the housing Make sure the o rings are sealed Replace the cap Reconnect the orange tubing Proceed as in para 8 1 h F Model PWC 3000 uses RO filter replace...

Страница 20: ...make sure that power cord is pulled out of socket 9 2 Remove the top cover hot water tank cover and the water outlet tube on main water tank Drain all remain ing water inside hot water tank and main water tank by pressing hot and warm water release levers Use a deep bowl to catch water flowing from valves Clean main water tank Sanitize as in section 9 4 9 3 Unscrew or pull the cap of the water out...

Страница 21: ...l device In this case send unit to local distributor for repair Heating cycle is more frequent than normal Too little water in hot water tank Refill main water tank Cold Water not cold enough The dispenser is placed too close to wall Wire Condenser on backside is dusty Unit is placed in poorly ventilat ed area Compressor does not have enough refrigerant Provide a minimum of 4 in space between wall...

Страница 22: ... gal Hot Water 500W Cold Water 100W 6Ft PWC 3000 AC110V L 16 x W 16 x H 42 52 lb 2 2 gal 8 gal 1 gal Hot Water 500W Cold Water 100W 6Ft Model No Voltage Frequency Dimensions Weight empty Hot Water Tank Capacity Cold Water tank Capacity Power Consumption Electric Power Cord Length PWC 1000 500 AC110V L 13 x W 16 x H 40 42 lb 5 gal 1 0 gal Hot Water 500W Cold Water 100W 6Ft Specification for Model n...

Страница 23: ...y for damage due to water leakage or other secondary effects from any component defect Labor is not covered in this warranty The warranty applies when Conditions of Operation below are met Conditions of Warranty Water System Pressure 35 100psi Temperature 40 100degrees F Water PH range 4 10 Max TDS 1500 PPM Turbidity 1 0 NTU Water Hardness 20gpg Iron 0 1 mg l Manganese 0 1 mg l Hydrogen Sulfide 0 ...

Страница 24: ...VERTEX WATER PRODUCTS Montclair Calif PWCM 1 Rev B 1 5 07 Copyright 2007 VERTEX Industrials Inc ...