– 5 –
4.0 Installation
4.1 Positioning the Cooler
There are some precautions to take when positioning and using the
PureWaterCooler™
. See the items in Figure 4a and 4b. In addition, the cooler must
be located near the supply water, and for the “R” version with the reverse osmosis fil-
ter, there must be access to a drain trap to which the reject water from the RO is deliv-
ered. Normally, this can be found in a bathroom, or kitchen sink. Flexible 1/4-inch
plastic tubing may be used for the feed and discharge connections. Normally, these
connections should be within 25-feet of the cooler.
Important Note:
Do not cover air intake vent as this will prevent proper chill-
ing from occurring.
Figure 4a.
Installation Precautions
6 in
4 in
Keep at least 6 in. distance between the cooler and the wall.
Air
Intake
vent