Vertex PureWaterCooler PWC-2000F Скачать руководство пользователя страница 23

PWC – 600/2000

PureWaterCooler

Copyright 2004 Vertex Water Products

The sanitization procedure is performed to reduce/eliminate any bacteriological 

growth in the cooler tanks and dispensing plumbing. Bacteriological growth
can be the cause of some taste in the water.

The procedure is as follows:

1.

Mix ½ teaspoon of common household bleach (5.25%) with 5 gallons of

clean water.

2.

Unplug the cooler from the power source.

3.

Drain all water from the cooler tanks.

4.

Pour the sanitizing solution into the main (room temperature) tank until full.

5.

Open all 3 spigots to allow sanitizing solution to fill the dispensing faucets.

Close the faucets.

6.

Let the sanitizing solution stand in the cooler for 10 minutes. 
CAUTION: Leaving the sanitizing solution in the cooler for more 
than 10 minutes can cause taste problems in the water.

7.

Completely drain the sanitizing solution from all the tanks.

8.

Fill the main (room temp.) tank with clear tap water to rinse out the 

sanitizing solution.

9.

Completely empty the rinse water from the tanks.

10.

The cooler is now sanitized and ready for use.

12. Sanitization Procedure

Содержание PureWaterCooler PWC-2000F

Страница 1: ...PWC 600 2000 PureWaterCooler Copyright 2004 Vertex Water Products SERVICE MANUAL for PureWaterCooler by Vertex Model PWC 600 2000 P N man 7006...

Страница 2: ...5 Remove Circuit board and Faucet Cover 6 Remove Replace Float Switch 7 Remove Replace Hot Tank 8 Remove Replace Faucet 9 Draining Cooler Tanks 10 Remove Replace Hot Tank Sensor 11 Remove Replace Cold...

Страница 3: ...e does not have insulation on the tank This version was produced up until November 2002 The heating pipe style of hot tank is recognized by the foam insulation on the circumference of the tank The hea...

Страница 4: ...s 2 Cooler Set Up for new cooler installation Remove Lower Front Panel Access Filters 2 1 Tilt cooler back NOTE For model PWC 3000 grab lower panel at bottom mid point and simply pull forward 2 2 Depr...

Страница 5: ...ooler 2 6 Connect supplied orange feed water tubing to feed connector on back of cooler 2 7 Connect orange line to cold water line figure 2 7 A self piercing saddle valve is provided to be the cold wa...

Страница 6: ...andard 1 drain pipe see fig 1 below 2 13 Turn on feed water at cold water line 2 14 Turn on feed water ball valve at filters 2 15 Plug in cooler Do not turn on hot tank at this time 2 16 Feed water so...

Страница 7: ...s 3 1 To replace front panel install bottom section on cooler base 3 2 Install center of upper section near drip tray 3 3 With palm of hand hit left and right side of upper panel to finish installatio...

Страница 8: ...ex Water Products 4 Remove top cover and back cover 4 1 Remove the round top cover 4 2 Firmly pull up on the main top cover to remove it NOTE on PWC 3000 model remove 2 holddown screws rear of main to...

Страница 9: ...00 PureWaterCooler Copyright 2004 Vertex Water Products 4 3 The Main Tank and float are now accessible 4 5 Back Cover 4 6 Remove 6 screw from back cover and lift off 4 Remove top cover and back cover...

Страница 10: ...Products 5 0 Push down firmly on the top portion of the faucet cover 5 1 The top part of the cover will disengage from the cooler 5 2 Carefully pivot the top of the cover forward and clear the 3 fauc...

Страница 11: ...ectors from the circuit board 5 4 The cover should now be free from the cooler and can be placed on a work bench 5 5 Remove 4 screws that hold the circuit board to the faucet cover Lift off circuit bo...

Страница 12: ...t Switch 6 1 Remove top lids from cooler 6 2 Remove main tank cover 6 3 Remove hot tank as described in this manual sec 7 6 4 Remove back panel 6 4 Remove 9 screws holding main tank to frame 6 5 Disco...

Страница 13: ...roducts 6 6 Tilt up edge of main tank to gain access to micro switch assembly 6 6 Disconnect electrical terminals from micro switch 6 7 Lift main tank out of cooler 6 8 Place main tank on work bench t...

Страница 14: ...erCooler Copyright 2004 Vertex Water Products 6 9 Remove micro switch by loosening and removing plastic nut 6 10 Remove washer and activator rod 6 11 Remove metal nut and silicon washer 6 Remove Repla...

Страница 15: ...eWaterCooler Copyright 2004 Vertex Water Products 6 12 Remove float mechanism from main housing 6 13 Complete Float assembly removed 6 14 Replace new float assembly in reverse order 6 Remove Replace F...

Страница 16: ...4 Vertex Water Products 7 Remove Replace Hot Tank for coolers built after 10 02 7 1 With cooler top cover off and back removed remove screws 5 places holding hot tank to main reservoir assembly 7 2 Re...

Страница 17: ...ectrical contactors from thermal sensors 4 places See Figure 2 for wiring schematic 7 4 Lower hot tank and remove 7 5 Disconnect 2 electrical connectors at bottom of tank 7 6 To install hot tank rever...

Страница 18: ...Remove faucet cover as shown in section 5 8 2 Remove silicon tubing from back of faucet by pulling and working it off 8 3 Remove plastic nut from rear of faucet using 7 8 socket 8 4 Once the nut is re...

Страница 19: ...Tank Drain Using a flat head screw driver pry the hot tank plug out until you can grasp it with your fingers 9 1 Remove the plug with fingers Water will pour from the port 9 2 Cold Tank and Main Tank...

Страница 20: ...ition unplug the cooler from main power disconnect one of the Electrical terminals on the sensor Using an ohm meter check for continuity IF there Is no continuity the sensor is bad and must be replace...

Страница 21: ...or The cold temperature switch includes the thermal sensor which is attached to The switch The sensor probe integral with the switch is inserted into the Receptacle at the bottom of the cold tank 11 0...

Страница 22: ...lly remove the sensor probe from the receptacle at the bottom of the hot tank 11 3 Disconnect 2 electrical terminal wires 11 4 Lift and remove switch assembly form mounting plate 11 5 Replace new swit...

Страница 23: ...r tanks 4 Pour the sanitizing solution into the main room temperature tank until full 5 Open all 3 spigots to allow sanitizing solution to fill the dispensing faucets Close the faucets 6 Let the sanit...

Страница 24: ...ocket 2 Power switch not on Make sure cold power button on on front panel is on 3 Adjust temperature control The thermostat temperature control adjustment is located on the right rear of the cooler 4...

Страница 25: ...ated 3 Electrical terminal Check to see that both wires are disconnected connected to the heating element terminals These are located at the bottom of the tanks 4 Heating element failure Check for con...

Страница 26: ...ensor and functions as an over heat safety The lower sensor is a 85 C sensor and controls the heating element function The lower sensor would be the problem if there was no hot water To see if the sen...

Страница 27: ...are Front Panel Lights Cause Check Hot Power on Heating element disconnected No Continuity across Heating on or burned out heating element No lights at all Upper thermal sensor disconnected No Continu...

Страница 28: ...dard gap between micro switch And rod To lower the water level in the tank bend the micro switch bracket towards the activator rod reducing the gap between the micro switch and the rod Bend bracket he...

Страница 29: ...VAC 60 Hz Weight dry 48 lbs Model PWC 600 2000 Total Water Capacity 3 2 gallons Room temp tank 2 2 gallons Hot tank 0 5 gallons Cold tank 0 5 gallons Power Consumption Total 600 Watts Hot Tank 500 Wat...