4.1 Positioning the Cooler
4.0 Installation
There are some precautions to take when positioning and using the
PureWaterCooler™.
See the items in Figure 4a and 4b. In addition, the
cooler must be located near the supply water. Flexible 1/4-inch plastic tubing
may be used for the feed connection. Normally, this connection should be
within 25-feet of the cooler.
Important Note:
Do not cover air intake vent as this will prevent proper chilling
from occurring.
Figure 4a.
Installation Precautions
Keep at least a 6 in. distance between the cooler and the wall.
6 in
Intake
vent
4
in
5
Air Intake
Vent
14
8.0 Filter Replacement
The filter elements must be replaced at regular intervals to maintain the quality
of the water.
The “F” Model 900F has 2-stages of mechanical filtration. A 1st stage
5-micron sediment filter and a 2nd stage activated carbon filter. Both stages
must be replaced every 6-12 months.
7.1 Sediment and Carbon Filter Replacement Procedure
a. Unplug the cooler from the wall socket.
b. To access the filter compartment, remove the two screws that secure the
right side panel. (See Figure 11).
c. Close Service ball valve (blue handle) by turning valve handle
perpendicular to flow tubing.
d. To remove the sediment and carbon filter cartridge, rotate the filter cartridge
1/4 turn and pull down.
e. Install a new carbon and sediment filter in the indicated positions.
Use these replacement filters for PWC 900F
1
st
stage Sediment filter, P/N TF-4113
2
nd
stage Carbon Block filter, P/N TF-4115
g. Plug in the power cord. Press cold dispense button and Let water run until
is clear.