Vertex Standard VXR-9000-H Скачать руководство пользователя страница 6

VXR-9000 FM R

EPEATER

 O

PERATING

 M

ANUAL

T

WO

 T

ONE

 D

EC

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Two Tone Dec” to turn the 2-Tone Decoder
“On” or “Off” (toggle).

CW ID S

INGLE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “CW ID Single” to send the station callsign,
via Morse Code, once. Programming of the callsign is
performed by your VERTEX STANDARD dealer.

CW M

ESSAGE

 1 - CW M

ESSAGE

 8

Press (or press and hold in for one second) the 

PF

 key

assigned to “CW Message 1 - 8” to send a pre-pro-
grammed Morse Code message on the transmitted sig-
nal. Programming of the message(s) is performed by
your VERTEX STANDARD dealer.

DC P

OWER

 S

AVE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “DC Power Save” to turn the DC Power
Save feature “On” or “Off” (toggle).

When DC Power Save feature is set to “ON,” activate
the various power save feature (determined from your
VERTEX STANDARD dealer) while the repeater oper-
ates from the Backup Power Source.

E

NCRYPTION

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Encryption” to turn off the Optional En-
cryption Unit temporarily.

E

NCRYPTION

 C

ODE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Encryption Code” to select the Encryption
Code (determined from your VERTEX STANDARD
dealer; require the 

FVP-35

 Rolling Code Encryption

Unit).

K

EY

 L

OCK

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Key Lock” to lock the repeater’s front panel
keys (except “Key Lock” key); this feature can be en-
abled to prevent repeater settings from being disturbed.

L

OCAL

 PTT

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Local PTT” to enable (“On”) or disable
(“Off”) operation using a 

PTT

 switch connected to the

front panel’s Microphone Jack.

M

ONITOR

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Monitor” to cancel CTCSS and DCS squelch
decoding, so as to enable reception of signals present on
the channel that do not contain a matching CTCSS tone
or DCS code.

M

ONITOR

 M

This function provides to “Monitor” to cancel CTCSS
and DCS squelch decoding, so long as the 

PF

 key as-

signed to “Monitor M” is pressed and held in.

M

ULTI

 T

ONE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Multi Tone” to switch the Tone Table be-
tween “Main” and “Sub.”

P

ANEL

 I

NDICATOR

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Panel Indicator” to turn the Front Panel’s
Illumination “On” or “Off” (toggle).

R

EMOTE

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Remote” to toggle the operating mode be-
tween the “

Remote

” mode and “

Local

” mode.

When the “

Remote

” mode is selected, the repeater op-

erates according to the control instructions received
from the external device (connected to the 

ACC

 jack on

the rear panel). While in the “

Local

” mode, the repeater

operates from the front panel’s 

PF

 keys.

R

EPEAT

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Repeat” to toggle the operating mode be-
tween the “

Repeater

” mode and “

Base Transceiver

mode.

For normal operation, set this key to the “

Repeat

” mode.

When the “

Base Transceiver

” mode is selected, you can

speak into the microphone to use this repeater as a trans-
ceiver.

R

ESET

Press (or Press and hold in for one second) the 

PF

 key

assigned to “Reset” to reset (same function as the

POWER

 switch “off” and “on”) the repeater.

P

ROGRAMMABLE

 F

UNCTION

 

(

PF

)

 K

EY

 D

ETAILS

4

FCC ID: K6610443250/IC ID: 511B-10443250

Vertex Standard Co., Ltd.

Содержание VXR-9000-H

Страница 1: ... Walker Street Cypress CA 90630 U S A YAESU EUROPE B V P O Box 75525 1118 ZN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Close Winchester Hampshire SO23 0LB U K VERTEX STANDARD HK LTD Unit 5 20 F Seaview Centre 139 141 Hoi Bun Road Kwun Tong Kowloon Hong Kong RACK MOUNT REPEATER FCC ID K6610443250 IC ID 511B 10443250 Vertex Standard Co Ltd ...

Страница 2: ...VXR 9000 FM REPEATER OPERATING MANUAL FCC ID K6610443250 IC ID 511B 10443250 Vertex Standard Co Ltd ...

Страница 3: ...amming or internal modifications SAFETY WARNINGINFORMATION The antenna s used for this transmitter must be fixed mounted on outdoor permanent structures with a separation distance of at least 74cm from all persons during normal operation and must not exceed an antenna gain of 0 dBd This device must be restricted to work related operations in an Occupational Con trolled RF exposure Environment not ...

Страница 4: ...communications network requirements Note that some functions may require the purchase of optional internal ac cessories The possible PF key features and func tions are explained on the pages to follow VOL Knob This control knob adjusts the output level of the front speaker and external speaker jack on the back panel TX Indicator This LED glows red when the repeater is transmit ting Numeric Display...

Страница 5: ...TCSS DCS Encoder On or Off toggle CTCSS DCSDEC Press or Press and hold in for one second the PF key assigned to CTCSS DCS Dec to turn the CTCSS DCS Decoder On or Off toggle CW ID Press or Press and hold in for one second the PF key assigned to CW ID to turn the CW Identifier feature On or Off toggle When the CW ID feature is set to On your station s callsign will be superimposed on the outbound si...

Страница 6: ...second the PF key assigned to Local PTT to enable On or disable Off operation using a PTT switch connected to the front panel s Microphone Jack MONITOR Press or Press and hold in for one second the PF key assigned to Monitor to cancel CTCSS and DCS squelch decoding so as to enable reception of signals present on the channel that do not contain a matching CTCSS tone or DCS code MONITOR M This funct...

Страница 7: ...Signal as programmed by your VERTEX STANDARD dealer TOT Press or press and hold in one second the PF key as signed to TOT to turn the Time Out Timer feature On or Off toggle When the TOT feature is set to On the repeater will return to the Receive mode automatically after a pre set time of continuous transmission determined via programming by your VERTEX STANDARD dealer TRANSMIT Press or Press and...

Страница 8: ...the duplexer The out put impedance requirement is 50 Ohms Main Power Source Connector The primary DC power source should be connected here The power requirements are 13 6 V DC at 12 Amps continuous duty External Speaker Jack This 3 5 mm 2 pin jack provides variable audio output for an external speaker The audio output impedance at this jack is 4 to 16 Ohms and the level varies according to the set...

Страница 9: ... 5 TX ATT This output is intended for controlling an external co axial switching relay It is an open drain output which can sink approx 1 5 A when active The delay time which is between the repeater cause to transmit mode and this port switches to ground can be programmed by your VERTEX STANDARD dealer Pin 6 DISC OUT ANALOG OUTPUT WIDE BAND 0 3 000 HZ Received signals with full system deviation pr...

Страница 10: ...NALOG OUTPUT FOR DATA COMMUNICATIONS 300 3 000 Hz This pin is an output for low speed receiving data sig nals typically 1200 bps with the data being extracted after the de emphasis and low pass filter stages Pin 23 RXD HIGH DIGITAL OUTPUT FOR DATA COMMUNICATIONS Max 5 kHz This pin is an output for high speed receiving data sig nals typically 9600 bps with the data being extracted immediately after...

Страница 11: ...en separate receive and transmit antennas are used high Q narrow band types may serve to minimize interaction NEVER TRANSMIT WITHOUT HAVING A TRANSMIT ANTENNA CONNECTED TO THE TX ANTENNA JACK OF THE REPEATER Equipment Location The VXR 9000 must be installed in a 19 inch Mounting Rack which will allow for free air flow around the heat sink on the rear apron at all times In warm climates the repeate...

Страница 12: ...panel While the repeater is oper ating from the Main Power Source a slight charging current will maintain battery charge In the event of an unexpected interruption of the Main Power Source the automatic power control circuit will automatically switch the repeater to the backup battery and opera tion will not be interrupted After prolonged operation from the battery Backup Power Source it should be...

Страница 13: ... A Blade Fuse Q0000075 1 Knob Cap RA0506900 6 Name Plate RA0508500 1 Operating Manual 1 Optional Accessories FIF 9 Inline Interface Box FVP 25 Encryption Unit FVP 35 Rolling Code Encryption Unit MD 11A8J Desktop Microphone MH 25A8J Hand Microphone FCC ID K6610443250 IC ID 511B 10443250 Vertex Standard Co Ltd ...

Страница 14: ...rmodulation 82 dB Wide 78 dB Narrow Image Rejection 90 dB Squelch Threshold 5 dBµ Audio Output 4 W 4 ohm Audio Distortion 3 Hum and Noise 55 dB Wide 50 dB Narrow Audio Frequency Response De emphasis 6 dB oct From 300 Hz to 3 kHz Conducted Spurious 80 dBm Transmitter RF Output Power 100 75 50 W High Mid Low Antenna Impedance 50 ohm Antenna Connector Type N Modulation Type 16K0F3E 11K0F3E System Dev...

Страница 15: ...ATING MANUAL Part 15 21 Changes or modifications to this device not expressly ap proved by Vertex Standard could void the user s authorization to operate this device FCC ID K6610443250 IC ID 511B 10443250 Vertex Standard Co Ltd ...

Страница 16: ...TEX STANDARD CO LTD All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO LTD Printed in Japan 0504s BE FCC ID K6610443250 IC ID 511B 10443250 Vertex Standard Co Ltd ...

Отзывы: