![Vertex Standard VXD-R70 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/vertex-standard/vxd-r70/vxd-r70_installation-manual_1007476017.webp)
Page 15
Chapter 4 Electrical Connections
After the
VXD-R70
Repeater has been mechanically installed, electrical connections must be
made. This involves making the following connections:
• AC power cord, and
• antenna coaxial cables
Figure 4-1 shows the position of the various connectors and connections on the rear panel of
the repeater.
Figure 4-1
: Locations of Connectors on the Rear Panel of the Repeater
4.1
Power Supply Connections
4.1.1
AC Input Power Connection
Do NOT apply AC power to the repeater at this time. Make sure that the cir-
cuit breaker associated with the AC outlet is turned to OFF.
NOTE
: The AC source must be installed near the equipment and must be easily accessible.
Each repeater ships with a 2.438 m (8 feet) 3-conductor line cord that connects the repeater to a
110/120/220/240 VAC source. Figure 4-1 shows the location where the AC line cord connects to the
repeater. Insert the 3-prong plug into a 110/120/220/240 VAC grounded outlet.
If an alternate line cord is required, obtain a suitable line cord, with fittings approved by the safety
testing agency in the end-use country, from a certified electrical parts supplier.