VOX On Level
This parameter is to align the “VOX On Level”.
Set the Sensitivity of the VOX circuitry's input audio detector.
1. Press the “VOX ON Level” button to start the align-
ment.
The VOX ON Level window will appear.
2. Then input the alignment value in the “New” box.
Default: 80
Input Range: 0 (Level Down) ~ 255 (Level Up)
3. Click the “OK” button, the data will be saved and the
alignment is complete.
TX MSK Level
This parameter is to align the modulation level of the ANI function.
1. Press the “TX MSK” button to start the alignment. The
TX MSK Level window will appear.
2. Then input the alignment value in the “New” box.
Default: 10
Input Range: 0 (Level Down) ~ 15 (Level Up)
3. Click the “OK” button, the data will be saved and the
alignment is complete.
Содержание VX-4500 Series
Страница 5: ...5 Block Diagram VX 4500 4600 Series VHF FM Transceiver Service Manual ...
Страница 23: ...MAIN Unit Lot 1 3 23 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram ...
Страница 26: ...MAIN Unit Lot 4 26 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram ...
Страница 30: ...30 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT A Unit VX 4500 Lot 1 2 ...
Страница 32: ...32 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT A Unit VX 4500 Lot 3 ...
Страница 34: ...34 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT A Unit VX 4500 Lot 4 ...
Страница 37: ...37 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT B Unit VX 4600 Lot 1 2 ...
Страница 39: ...39 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT B Unit VX 4600 Lot 3 ...
Страница 41: ...41 VX 4500 4600 Series VHF FM Transceiver Service Manual Circuit Diagram FRONT B Unit VX 4600 Lot 4 ...