background image

FCC ID: K6630493X20 
IC: 511B-30493X20 

Alignment 

 

Vertex Standard Co., Ltd. 

2

Required Test Equipment   

ˆ

  RF Signal Generator with calibrated output level at 200 MHz 

ˆ

  Deviation Meter (linear detector)   

ˆ

 AF 

Millivoltmeter 

 

ˆ

 SINAD 

Meter 

ˆ

  Inline Wattmeter with 5% accuracy at 200 MHz 

ˆ

  Regulated DC Power Supply: 0V to 10 VDC, 5A 

ˆ

  50-ohm Non-reactive Dummy Load: 10 W at 200 MHz 

ˆ

  Frequency Counter: > 0.1 ppm accuracy at 200 MHz 

ˆ

  AF Signal Generator   

ˆ

  DC Voltmeter: high impedance 

ˆ

  VHF Sampling Coupler 

ˆ

  AF Dummy Load: 8 Ohms, 1 W   

ˆ

 Oscilloscope 

ˆ

 Spectrum 

Analyzer 

ˆ

 HX300 

Marine 

Transceiver 

ˆ

  IBM® PC/compatible computer with Microsoft® Windows® 2000, XP, or Vista 

ˆ

  Standard Horizon HX300 Service Flag Controller Program and Alignment Jig. 

 

Alignment Preparation & Precautions 

A dummy load and inline wattmeter must be connected to the main antenna jack in all 

procedures that call for transmission. Correct alignment is not possible with an antenna.   

After completing one step, read the following step to determine whether the same test 

equipment will be required. If not, remove the test equipment (except dummy load and 

wattmeter, if connected) before proceeding. 

Correct alignment requires that the ambient temperature be the same as that of the 

transceiver and test equipment, and that this temperature be held constant between 68 °F 

and 86 °F (20 °C and 30 °C). When the transceiver is brought into the shop from hot or cold 

air it should be allowed some time for thermal equalization with the environment before 

alignment. If possible, alignments should be made with oscillator shields and circuit boards 

firmly affixed in place. Also, the test equipment must be thoroughly warmed up before 

beginning. 

Note: 

Signal levels in dB referred to in this procedure are based on 0 dBµ = 0.5 µV 

(closed circuit). 

 

Содержание HX300

Страница 1: ...complete performance checks to ensure compliance with factory specifications after replacing any faulty components Those who do undertake any of the following alignments are cautioned to proceed at their own risk Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Also Standard Horizon a division of Vertex Standard must reserve the right to change circuit...

Страница 2: ... connected to the main antenna jack in all procedures that call for transmission Correct alignment is not possible with an antenna After completing one step read the following step to determine whether the same test equipment will be required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be th...

Страница 3: ...ware Alignment Mode The Software Alignment Mode has been build in the microprocessor in order to adjust and confirm the performance of transceiver The purpose is to adjust transceiver simply and to confirm the performance of transceiver smoothly Starting the alignment mode Set the channel to CH16 and then press the PWR switch while press and holding the PRESET keys Adjustment of PLL frequency Conn...

Страница 4: ...signal output level to 200mVrms at 1kHz Press the SCAN DW key till Md is displayed Press or keys while pressing the PTT key to set the deviation to 4 4 0 1kHz Press VOL SQL key to fix the alignment data Adjustment of the Reference modulation Connect the linear detector to the antenna jack and connect the AF signal generator to the Alignment Jig Set the AF signal output level to 1000mVrms at 150Hz ...

Страница 5: ...ion 3 0kHz deviation 1kHz modulation Set the output level to 7dBµ Press the SCAN DW key till tH is displayed Press PRESET key to obtain the squelch threshold level Press VOL SQL key to fix the alignment data This completes the Software Alignment Mode To save all settings and exit press and hold the 16 9 key for one second Then turn off the transceiver After Alignment Execute the HX300 Service Flag...

Отзывы: