Alignment

 

Required Test Equipment 

The following test equipment (and thorough familiarity with its correct use) is necessary for 

complete realignment. Correction of problems caused by misalignment resulting from use 

of improper test equipment is not covered under the warranty policy. While most steps do 

not require all of the equipment listed, the interactions of some adjustments may require 

that more complex adjustments be performed afterwards. Do not attempt to perform only a 

single step unless it is clearly isolated electrically from all other steps. Have all test 

equipment ready before beginning, and follow all of the steps in a section in the order 

presented. 

 

 

Regulated DC Power Supply: adjustable from 10 to 17 VDC, 15 A 

 

RF Signal Generator with calibrated output level at 500 MHz 

 

Frequency Counter: ±0.1 ppm accuracy at 500 MHz 

 

AF Signal Generator 

 

SINAD Meter 

 

Oscilloscope 

 

Spectrum Analyzer 

 

Deviation Meter (linear detector) 

 

AF Milivoltmetr 

 

AF Dummy Load: 4 

Ω

, 5 W 

 

DC Voltmeter: high impedance 

 

Inline Wattmeter with 5% accuracy at 500 MHz 

 

50-Ohm non-reactive Dummy Load: 100 watts at 500 MHz 

 

VHF/UHF Sampling Coupler 

 

Alignment Preparation & Precautions 

A dummy load and inline wattmeter must be connected to the main antenna jack in all 

procedures that call for transmission, except where specified otherwise. Correct alignment 

is not possible with an antenna. After completing one step, read the following step to 

determine whether the same test equipment will be required. If not, remove the test 

equipment (except dummy load and wattmeter, if connected) before proceeding. 

Correct alignment requires that the ambient temperature in the repair shop be the same as 

that of the transceiver and test equipment, and that this temperature be held constant 

between 20 °C and 30 °C (68 °C to 86 °F). When the transceiver is brought into the shop 

from hot or cold air it should be allowed some time for thermal equalization with the 

environment before alignment. If possible, alignments should be made with oscillator 

Vertex Standard Co., Ltd. 

Содержание FTM-10SR

Страница 1: ...d only by authorized Yaesu service technicians who are experienced with the circuitry and fully equipped for repair and alignment Therefore if a fault is suspected contact the dealer from whom the transceiver was purchased for instructions regarding repair Authorized Yaesu service technicians realign all circuits and make complete performance checks to ensure compliance with factory specifications...

Страница 2: ...nalyzer Deviation Meter linear detector AF Milivoltmetr AF Dummy Load 4 Ω 5 W DC Voltmeter high impedance Inline Wattmeter with 5 accuracy at 500 MHz 50 Ohm non reactive Dummy Load 100 watts at 500 MHz VHF UHF Sampling Coupler Alignment Preparation Precautions A dummy load and inline wattmeter must be connected to the main antenna jack in all procedures that call for transmission except where spec...

Страница 3: ...io signal as a level of 50 mV to the microphone input port Key the transmitter on 146 05 and 440 05 MHz Adjust the frequency deviation is within 4 0 4 4 kHz on the deviation meter CTCSS Deviation With the wattmeter dummy load and deviation meter connected to the antenna jack Key the transmitter on 146 05 and 440 05 MHz Adjust the frequency deviation is within 0 65 0 75 kHz on the deviation meter D...

Страница 4: ... within 1 0 5 W on the power meter LOW Key the transmitter on 440 05 MHz Adjust the output power is within 7 0 5 W on the power meter HI Key the transmitter on 440 05 MHz Adjust the output power is within 5 0 5 W on the power meter MID Key the transmitter on 440 05 MHz Adjust the output power is within 1 0 5 W on the power meter LOW Receiver Sensitivity With the dummy load and SINAD meter connecte...

Отзывы: