SECTION 5

MAINTENANCE AND TROUBLESHOOTING

5.1

INTRODUCTION

This chapter contains general information designed to isolate a malfunction in the Model F270X to a

replaceable unit.  These units are not equipped with redundancy.  Therefore, a failure in one of these units would
interrupt service.

5.2

FAULT ISOLATION

The steps in Table 12 should be taken to check a nonoperating Modem.  Contact VERSITRON

Customer Service for additional diagnostic assistance or to arrange for repair as necessary.

STATUS INDICATOR

PROBABLE CAUSE

CORRECTIVE ACTION

No AC power

Check that both ends of the transformer are
connected

Blown Fuse

Replace with 250V 1A slo-blo fuse

POWER (PWR) LED is OFF

Other power supply circuit problem

Contact VERSITRON for assistance
1.

 

Check that fiber optic cables are properly
connected

2.

 

Check that the remote unit power is on and the
fiber optic connectors are properly attached

3.

 

Measure the optical levels on both ends (if
possible) in order to check the optical link

ALARM (ALM) LED is ON

Incorrect optical signal level received at
receiver input

4.

 

Contact VERSITRON for assistance

HOOK LED is ON

Possible problems ranging from a
telephone set in an Off-Hook position to
a problem with the Off-Hook circuit

Check if the telephone set receiver is seated in the
cradle correctly. If this is not the case, contact
VERSITRON for assistance

LOOP LED is ON

Current supplied by the central office is
fluctuating from 17mA to 25mA

Check the exchange the exchange line coming from
the central office or the Switch

RBAT LED is ON

Voltage between Tip and Ring are
reversed

Check that the Tip and Ring on the 2-wire UTP
coming from the central office are not reversed. That
is, Tip wire is not connected to the Ring on the
Modem’s RJ11 connector and vise versa

Modem is not working properly

Default jumpers and switch settings are
not set properly

1.

 

Check if SW1-1 is OFF and JP3 is not removed

2.

 

Check if SW2 is properly set for the desired
interface (i.e. copper or fiber network
application, see table 4)

3.

 

Contact VERSITRON for assistance

TABLE 11:  NONOPERATIONAL INDICATORS

Содержание F270 Series

Страница 1: ...A020519685 F270X Fiber Optic Tele Data Modem Technical Manual Revision B Copyright May 2002 VERSITRON Inc 83 Albe Drive Suite C Newark DE 19702 www versitron com...

Страница 2: ...1 are warranted for a period of one year from date of delivery VERSITRON reserves the right to repair or at our option replace parts which during normal usage prove to be defective during the warranty...

Страница 3: ...ON 2 1 GENERAL 6 2 2 SITE SELECTION AND MOUNTING 6 2 3 SWITCH AND JUMPER SETTINGS 6 2 3 1 RS 485 RS 422 Data Transmission Settings 6 2 3 2 Fiber Optic or Copper Transceiver Network Settings 7 2 3 3 In...

Страница 4: ...2 4 3 FUNCTIONAL DESCRIPTION 13 4 3 1 Ring Detection 13 4 3 2 Loop Current Detection Circuit 13 4 3 3 Reverse Battery Detection Circuit 13 4 3 4 Analog to Digital Conversion 13 4 3 5 CPLD Mux Demux 13...

Страница 5: ...DC POWER SUPPLY CONNECTIONS 8 LIST OF TABLES TABLE TITLE PAGE 1 DIMENSIONS OF ENCLOSURES AND CHASSIS 2 2 SW1 SWITCH SETTINGS 6 3 JP4 JUMPER SETTINGS 7 4 SW2 SWITCH SETTINGS 7 5 LINE IMPEDANCE JUMPER...

Страница 6: ...optics 14 Km operational distance 1 2 DESCRIPTION OF EQUIPMENT 1 2 1 Functional Characteristics The Model F270X Fiber Optic Modems are designed to be used as an interface extender from a single line e...

Страница 7: ...include both single and dual card enclosures Rack mount options include a 2 card and 20 card 19 standard rack mountable chassis For either desktop enclosure or 2 card rack mount chassis each F270X F2...

Страница 8: ...FRONT VIEW F270X MODEM FIGURE 1 2 REAR VIEW F270X MODEM FIGURE 1 3 BACK PANEL F270X MODEM RJ11 RJ45 TX RX RJ11 Power Jack Audio Jack 2 Wire Data Jack Optical Interface Copper Interface 4 Wire 12Pin Co...

Страница 9: ...ber Modem DataCom Product i e PLC Copper Interface Fiber Interface Fiber or copper cable interfaces depending on the application Fiber Interface Copper Interface Full duplex 4 Wire Twisted Pair RS 485...

Страница 10: ...40dBm Out Band Spurious 30dBm Talk Battery 45 to 55 VDC Loop Current 20mA max off hook Ring Signal 80 150VAC 15 to 68Hz Line Impedance Jumper selectable 600 or 900 Fiber Optic Interface Models F2702 F...

Страница 11: ...isconnection Care should be taken to ensure that the copper and fiber optic cables are not mechanically separated from the Modem during operation When installed in either desktop chassis or in the dua...

Страница 12: ...r a copper 4 wire twisted pair or a fiber optic interface is accomplished by the following dip switch settings Position Copper Interface Fiber Interface SW2 1 On Off SW2 2 Off On SW2 3 On Off SW2 4 Of...

Страница 13: ...igned to operate from an AC power transformer or a DC power source in the range of 12 to 18 VDC 2 4 1 Installation with AC Power Before inserting the VERSITRON power transformer PSAC08 US or PSAC09 EU...

Страница 14: ...is used for RS 485 or RS 422 data transmission Wiring for J5 is shown in Table 9 RJ11 J6 is used in applications where data audio or both are meant to transmit on a copper instead of fiber optic netw...

Страница 15: ...scriber side Modem F271X On the other hand the F271X transmitter optic should be connected to the F270X receiver optic 2 6 INITIAL CHECKOUT PROCEDURE F270X Series Modems contain no power on off switch...

Страница 16: ...P reverse battery RBAT alarm ALM No audible alarm is available LEDs Color Function PWR Green Indicates operating voltage is present at the power interface connector HOOK Red Indicates that the telepho...

Страница 17: ...C28 1800pF and an under voltage lockout feature This feature is produced by CR5 1N755 and CR6 1N4148 The under voltage lockout is accomplished as follows When the input voltage becomes lower than the...

Страница 18: ...y from 17mA to 25mA When this condition is present U13 optocoupler detects the current and discharges C23 68 F to trigger the LOOP signal or LED 4 3 3 Reverse Battery Detection Circuit Normally Tip is...

Страница 19: ...FET VN10KM the fiber optic transmitter Z2 is turned on and off respectively This is how the optical signal is transmitted out of the Modem On the receive side optical receiver Z1 takes the optical sig...

Страница 20: ...th ends if possible in order to check the optical link ALARM ALM LED is ON Incorrect optical signal level received at receiver input 4 Contact VERSITRON for assistance HOOK LED is ON Possible problems...

Отзывы: