background image

vda050710sdsm-rev0419

7

 • Surge Dampeners

www

.

versamatic

.

com

 ITEM  PART 

 

TOTAL

 NO.  NUMBER 

DESCRIPTION 

RQD.

 

196-161-552  Chamber, Outer 

1

   

196-161-520  Chamber, Outer 

1

   

196-161-542  Chamber, Outer 

1

 

   

196-171-110  Chamber, Outer (VDA05 Metallic only) 

1

 

   

196-171-157  Chamber, Outer (VDA05 Metallic only) 

1

  2 

334-103-552  Flange, Threaded ½" NPT (VDA05) 

2

   

334-103-542  Flange, Threaded ½" NPT (VDA05) 

2

   

334-103-600  Flange, Threaded ½" NPT (VDA05) 

2

   

334-109-110  Flange, Threaded ½" NPT (Metallic VDA05 only) 

2

 

   

334-109-150  Flange, Threaded ½" NPT (Metallic VDA05 only) 

2

   

334-104-552  Flange, Threaded ¾" NPT (VDA07) 

2

   

334-104-542  Flange, Threaded ¾" NPT (VDA07) 

2

   

334-104-600  Flange, Threaded ¾" NPT (VDA07) 

2

   

334-107-552  Flange, 1" ANSI (VDA10) 

2

  3 

135-022-115  Bushing, Reducer 

2

  4 

196-166-552  Chamber, Inner 

1

 

 5

 

720-058-600  Seal, Flange 

2

 

   

720-063-600  Seal, Flange (Metallic VDA05 only) 

2

 

286-097-600 Diaphragm 

 

171-064-115  Capscrew Hex Flange 5/16 -18 x 1.50 

8

   

171-064-308  Capscrew Hex Flange 5/16 -18 x 1.50 

8

 

   

170-029-330  Capscrew, Hex Flange 5/16 x 1.50 (Metallic VDA05 only)  4

  8 

544-005-115  Nut 5/16 Hex Flange Nut 5/16-18 

10

   

544-005-308  Nut 5/16 Hex Flange Nut 5/16-18 

10

 

   

545.004-330  Hex Flange Nut (Metallic VDA05 only) 

10

  9 

171-070-115  Capscrew Hex Flange 5/16 -18 x 3.00 

6

   

171-070-308  Capscrew Hex Flange 5/16 -18 x 3.00 

6

 

   

171-070-330  Capscrew, Hex Flange (Metallic VDA05 only) 

2

  10 

171-069-115  Capscrew Hex Flange 5/16 -18 x 2.5 

2

   

171-069-308  Capscrew Hex Flange 5/16 -18 x 2.5 

2

 

   

171-069-330  Capscrew, Hex Flange (Metallic VDA05 only) 

2

  11 

538-002-115  Nipple 1/8 NPT 

1

  12 

020-039-000  Regulator W/Gauge 

1

  13 

170-045-330  Capscrew Hex Flange (VDA05 Metallic Only) 5/16 -18 x 1.25 4

  14 

900-004-330  LockWasher (VDA05 Metallic Only) 

14

  15 

901-038-115  Flat Washer (Non-Metallic Only) 

2

Repair Parts shown in 

bold face (darker) 

type  are  more  likely  to  need  replacement 
after extended periods of normal use. They 
are readily available from most Versa-Matic 
distributors. The pump owner may prefer to 

maintain a limited inventory of these parts 

in his own stock to reduce repair downtime 

to a minimum.

IMPORTANT: 

When ordering repair parts 

always furnish pump model number, serial 
number and type number.

MATERIAL CODES

The Last 3 Digits of Part Number

000...  Assembly, sub-assembly; and some

 

purchased items 

110... 

CF*M (316) Stainless Steel

115... 

302/304 Stainless Steel 

157... 

380/383 Die Cast Aluminum

308...  Stainless Steel; Black PTFE Coated 

330... 

Zinc Plated Carbon Steel

360... 

Nitrile Rubber. Color coded: RED

520...  Injection Molded PVDF, Natural Color,

542... Nylon

552... Polypropylene

600... 

Virgin PTFE

Composite Repair Parts List

Содержание VDA

Страница 1: ...pp Inc A Unit of IDEX Corporation Copyright 2019 Warren Rupp Inc All rights reserved SERVICE OPERATING MANUAL ORIGINAL INSTRUCTIONS 800 North Main Street Mansfield OH 44902 USA Phone 419 526 7296 www...

Страница 2: ...es the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended t...

Страница 3: ...CIFICATIONS 1 Dimensional Drawings SECTION 2 INSTALLATION OPERATION 2 Principle of Pump Operation Service Typical Installation Guide SECTION 3 EXPLODED VIEW 4 Composite Drawings Parts List Material Co...

Страница 4: ...19 3 Surge Dampeners www versamatic com DA05 1 2 NPT BSP THREADED PORT 1 2 NPT BSP THREADED PORT DA07 3 4 NPT BSP THREADED PORT 3 4 NPT BSP THREADED PORT VDA10 VDA07 VDA05 Metallic and Non Metallic Di...

Страница 5: ...n PTFE 35 F 31 C 212 F 100 C Nitrile 10 F 23 C 190 F 88 C INSTALLATION START UP Locate the unit in the discharge piping near the pump The dampener will operate in any position However when used with l...

Страница 6: ...st air causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air sh...

Страница 7: ...amatic com Composite Repair Parts Drawing Supplied with regulator Nameplate location 12 15 11 3 9 10 15 10 9 4 6 1 13 13 2 5 8 8 5 2 7 Diaphragms must be installed as shown with convolutions facing th...

Страница 8: ...1 070 115 Capscrew Hex Flange 5 16 18 x 3 00 6 171 070 308 Capscrew Hex Flange 5 16 18 x 3 00 6 171 070 330 Capscrew Hex Flange Metallic VDA05 only 2 10 171 069 115 Capscrew Hex Flange 5 16 18 x 2 5 2...

Страница 9: ...y conformance EN809 2012 Ce materiel est fabriqu selon les normes harmonis es suivantes afin d en garantir la conformit Este producto cumple con las siquientes directrices de la comunidad europa Diese...

Отзывы: