System Features
EBX-18 Hardware Reference Manual
18
Lithium Battery
Nominal battery voltage is 3.0V. If the voltage drops below 2.7V, contact the factory for a
replacement. The life expectancy under normal use is approximately five years.
CAUTION:
To prevent shorting, premature failure or damage to the Lithium battery, do not
place the board on a conductive surface such as metal, black conductive foam
or the outside surface of a metalized ESD protective pouch. The Lithium
battery may explode if mistreated. Do not recharge, disassemble, or dispose of
the battery in fire. Dispose of used batteries promptly.
B
ATTERY
S
AVER
J
UMPER
The EBX-18 includes a “Battery Saver” jumper at location V13. This jumper keeps the Lithium
battery from discharging (keeping it disconnected) before the EBX-18 board is in the customer’s
hands and ready to be used. The default configuration of the jumper is a no-connect position
(placed only on pin 1). Figure 8 shows the location of the V13 Battery Saver Jumper.
Table 6: Battery Saver Jumper Truth Table
V13 Jumper Position
Condition
Pin 1 only (default)
Battery is disconnected
(not discharging)
Pin 1-2
Battery is connected
Figure 8. Location of the V13 Battery Saver Jumper