Distributor of VersaLogic Corporation: Excellent Integrated System Limited
Datasheet of VL-EPMS-PS1A - SUMIT-104, POWER SUPPLY 50 W
Contact us: [email protected] Website: www.integrated-circuit.com
Operation
EPMs-PS1 Reference Manual
17
Power Supply Control
Individual voltage outputs can be disabled using the disable lines on the J7 connector. The J7
connector is a series of four two-pin, 5.08 mm screw terminals accepting AWG 16-14 insulated
wire.
All output voltages are on by default. To turn off a voltage, tie the voltage disable pin directly to
ground. Disabling the +5V output turns off all outputs.
Table 7: Power Supply Control Connector Pinout
J7
Pin
Signal
5 +12V
Disable
6 -12V
Disable
7 +5V
Disable
8 Ground
Efficiency and Derating
Figure 9. Power Supply Efficiency over V
IN
and Load
22 / 24
22 / 24