Prepare the Site for Installation

To prepare your site for installing a CSG300 series appliance, follow the guidelines and requirements listed in this
article.

Site Preparation Guidelines

• Install the appliance in an enclosed and secure environment, and allow only authorized personnel to access the

device.

• Keep the area around the appliance free from dust and conductive material.

• Follow ESD prevention procedures to avoid any damage to the appliance.

Environmental Requirements

• Ensure that the area in which you operate the appliance has adequate air circulation so that the cooling system

functions normally. Ambient air temperature may not be sufficient to cool the chassis to acceptable operating
temperatures without adequate circulation.

• Avoid temperature extremes.

• High humidity conditions can cause moisture to penetrate into the chassis. The appliance can operate in relative

humidity of 10% to 85%, non-condensing.

Rack Requirements

You can mount a CSG300 series appliance in a 19-inch four-post rack using slide rails. Table 1 lists the rack
requirements.

Table 1: Rack Requirements for a CSG300 Series Appliance

Requirement

Guidelines

Rack type

Use a 19-inch four-post rack that has bracket holes spaced at 1 U (1.75 in. or 4.45 cm) increments,
and that has panels strong enough to support the weight of the appliance.

Rack size

Comply with the size and strength standards of a 19-inch rack. Ensure that the rack rails are spaced
wide enough to accommodate the external dimensions of the appliance chassis. Ensure that the
spacing of rails and the adjacent racks allows for proper clearance around the appliance and the
rack.

Rack firmly

Secure the rack to floor brackets and to ceiling brackets to ensure maximum stability.

https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/02_Prepare_the…

Updated: Wed, 01 Apr 2020 19:00:38 GMT

Powered by

1

Содержание CSG300 Series

Страница 1: ...ble in a 19 rack CSG300 Appliance Models The CSG300 appliances are available in the following models CSG350 Compact and optimized appliance for deployment in small branches up to 75 users that require...

Страница 2: ...iance Note The front panel is the side of the appliance with the SIM slots and two LEDs for status and power This is the side that is visible when you install the appliance in an office environment Th...

Страница 3: ...Figure 4 Rear Panel of the CSG355 Appliance https docs versa networks com Hardware Cloud_Services_Gateway_300_Series Overview At_a_Glance Updated Tue 31 Mar 2020 19 09 37 GMT Powered by 3...

Страница 4: ...assis Table 1 CSG350 Series Chassis Specifications Item Specification Services and Slot Density RJ 45 ports 10 100 1000 Mbps 4 External USB ports USB 2 0 1 RJ 45 serial console port 1 Memory DDR4 ECC...

Страница 5: ...e 0 to 40 C 32 to 104 F at sea level Humidity 10 to 85 relative humidity Altitude Maximum 3000 m 10000 ft Noise level Less than 20 dBA Storage Conditions Temperature 20 to 70 C 68 to 158 F at sea leve...

Страница 6: ...e 2 CSG355 and CSG365 Chassis Specifications https docs versa networks com Hardware Cloud_Services_Gateway_300_Series Components_and_Specifications 01_CSG Updated Tue 31 Mar 2020 17 58 46 GMT Powered...

Страница 7: ...voltage 100 240 Volts AC input line frequency 50 60 Hz Typical power consumption 33 Watts Chassis Physical Specifications Chassis height 1 65 43 mm Chassis width 13 8 370 mm Chassis depth 6 7 172 mm R...

Страница 8: ...ability MTBF Minimum of 70 000 hours Regulatory Compliance Table 2 lists the regulatory compliance specifications for a CSG300 series chassis Table 2 CSG300 Series Regulatory Compliance Specifications...

Страница 9: ...nce Japan has completed their testing Export Control Information Table 4 lists the ECCN HTS and CCATS numbers Table 4 ECCN HTS and CCATS Numbers Item ECCN Number HTS Number CCATS Number Use of item by...

Страница 10: ...HTS Number CCATS Number Use of item by Versa appliance https docs versa networks com Hardware Cloud_Services_Gateway_300_Series Components_and_Specifications 01_CSG Updated Tue 31 Mar 2020 17 58 46 G...

Страница 11: ...Status Green Red Off Appliance hardware is up but there is a problem with the software Solid green Appliance is up and running Blinking green Appliance is in the process of booting up Red Major error...

Страница 12: ...eless module LTE White Off LTE module not installed or there is a major hardware problem Solid white LTE module is up and running Blinking white LTE module is booting up or there is traffic on the LTE...

Страница 13: ...button is recessed so that it is not accidentally pressed while the appliance is operational To press the Reset button use a sharp narrow tool Each time you press the Reset button you hear a buzzer s...

Страница 14: ...twork If a SIM card is inserted from carrier B the modem will connect to the network of carrier B Global navigation satellite system GNSS receiver enables tracking and location based services Stores u...

Страница 15: ...slot which is on the front of the appliance For modules with two SIM slots you insert a SIM card into each of the two SIM slots which are labeled SIM1 and SIM2 If the appliance is off when you insert...

Страница 16: ...ground scanning automatically selects the best and cleanest channel Up to 512 concurrent clients across both frequencies while each radio supports up to 255 clients Up to 16 SSIDs simultaneously Clien...

Страница 17: ...I Mapping CSG350 Figure 2 shows port to VNI mapping for the CSG355 and CSG365 Note that the CSG355 and CSG365 chassis are identical Figure 2 Port to VNI Mapping CSG355 and CSG365 https docs versa netw...

Страница 18: ...bled 35 Watts Typical power consumption with PoE enabled 60 Watts Airflow Requirements The CSG300 series appliance is made of aluminum for optimal heat dissipation The appliance is cooled by a fan Whe...

Страница 19: ...installing or removing it Disconnect power from the circuit that is being used for the appliance If hazardous conditions exist do not work alone If you are working under conditions that might be haza...

Страница 20: ...ges or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be collocated or operating in co...

Страница 21: ...The appliance can operate in relative humidity of 10 to 85 non condensing Rack Requirements You can mount a CSG300 series appliance in a 19 inch four post rack using slide rails Table 1 lists the rack...

Страница 22: ...series appliance in a 19 inch rack or on a desk ensure that the vents on the side of the unit are never blocked to allow hot air to flow out of the appliance Covering the vents prevents heat from diss...

Страница 23: ...dy to install it To unpack a CSG300 series appliance 1 Open the top flaps of the cardboard carton 2 Remove from the box the foam packing material holding the appliance and the accessories in place See...

Страница 24: ...nce Table 1 Parts Shipped with a CSG350 Series Appliance Components Quantity CSG300 series appliance chassis 1 AC power adapter 1 Power cable 1 Cat 6 cable 1 Cat 5e cable 1 LTE antenna included with L...

Страница 25: ...iance ensure that you have the following tools Number 2 Phillips screwdriver Tape measure To mount a CSG300 series appliance in a four post 19 inch rack 1 Place the appliance chassis on a flat stable...

Страница 26: ...ront of the rack and lift the chassis Then gently insert the chassis into the rack and slide it as far back as possible Figure 4 Insert a CSG300 Series Appliance into the Rack 7 Have the second person...

Страница 27: ...https docs versa networks com Hardware Cloud_Services_Gateway_300_Series Planning_and_Installation 03_Install_a_CS Updated Wed 01 Apr 2020 19 02 26 GMT Powered by 5...

Страница 28: ...to a CSG300 series appliance ensure that you have Electrostatic discharge ESD wrist strap AC power cord shipped with the appliance The cord has plugs appropriate for your geographical location To con...

Страница 29: ...l of the CSG300 series appliance 2 Plug the other end of the cable into the console server or into a management console https docs versa networks com Hardware Cloud_Services_Gateway_300_Series Plannin...

Страница 30: ...nd model numbers of the appliance Physical location of the appliance Your name organization name telephone number fax number and shipping address Failure or problem description with details To obtain...

Страница 31: ...n the plastic packing bag 5 Secure the chassis in the cardboard carton placing the side packing foam on both sides of the appliance chassis and the top packing foam over the top 6 Close the cardboard...

Отзывы: