background image

I N D I A ' S  F I R S T

S U P E R  E F F I C I E N T  FA N

USER MANUAL

Congratulations  for  becoming  an  owner  of  the 
SUPERFAN. You have made an excellent choice and 
we hope you enjoy all its capabilities. 

This user manual explains how to use SUPERFAN. 
Please  read  this  manual  before  operating  your 
Superfan  and  keep  it  for  your  future  reference. 
Thank You.

VERSA DRIVES PRIVATE LIMITED.

LIST OF FAN PARTS

V1.1 Mar, 2013,

Revision: 

Air  delivery  and  power  specifications  changed  in 

section 1.2 and the mounting height from ceiling is mentioned.

PATENT PENDING.

Unpack the carton of Superfan and check whether 

you have the following items.

1. Down rod

2. Top canopy

3. Bottom canopy

4. Shackle kit to fix the down rod with ceiling hook

5. Kit to fix the down rod with fan motor

6. Fan motor with leaf fixing screws

7.  Remote  (6  key  or  9  key  remote  based  on  the 

model of Superfan)

8. Leaf – 3 No’s.

5

4

1

2

TM

3

TM

8

6

7

T

M

BEFORE INSTALLING AND OPERATING YOUR 

S U P E R FA N ,   P L E A S E   R E A D   S A F E T Y  

INSTRUCTIONS CAREFULLY.

• Before installing or cleaning the fan, switch off 

the  power  at  the  electricity  panel  and  the 
associated wall switch location

• Lock the electricity panel or securely fasten a 

warning device, such as a tag to prevent power 
from being switched on accidentally

• Wirings must be done by qualified electricians 

only

SAFETY INSTRUCTIONS

• The fan must be mounted at 

minimum height 

of 1 foot from ceiling and 7 feet from the 
floor

 to prevent accidental contact with the fan 

leaves.

• Do  not  bend  the  leaves  while  installing  or 

cleaning.

• Store  the  remote  battery  in  a  place  where 

children  cannot  reach.  If  a  child  accidentally 
swallow’s  the  battery  consult  the  doctor 
immediately.

• Dispose the battery in a proper manner. Do not 

dispose it in fire.

• Do  not  short  or  disassemble  the  remote 

battery.

Superfan is India’s first super-efficient fan which is 

designed to consume less amount of energy even 

at high speed. Hence it will reduce your electricity 

bill.

1.1. INTRODUCTION:

1.2. SPECIFICATIONS

SPECIFICATIONS  ARE  SUBJECT  TO  CHANGE 

WITHOUT NOTICE

1.3. FEATURES

•  Energy  saving,  more  than  50%  savings,  lower 

electricity bill.

• Sensor-less design for more reliability.
• Green manufacturing (ROHS electronics, VOC free 

paint, Green packing).

• Remote control for speed command, no regulator 

needed, save space on switch board.

• Indication of remote operation.
• High speed, high volume of air.
• Consistent  speed  in  low  voltage  and  varying 

voltages.

• Power factor better than 0.9 and more air per watt.
• Less heat generated by fan motor, cool operation.
• No  extra  noise  during  operation  from  inverter 

supply.

• More hours of operation with inverter.
• 2 years of warranty.

SUPERFAN  CAN  BE  POWERED  ON/OFF  BY 
USING A SIMPLE WALL SWITCH

Please  do  not  connect  any  regulator  to 
your Superfan

Phase & 
Neutral
wires

Fig 4

Terminal 
Block

Fig 3

Washer 
and nut

Cotter pin

Fig 2

Shaft

Slit end

Down rod

Fig 1

1.

 Take out the fan motor

 and place it 

gently on a clean and soft surface.

 2.

 Fix the slit end 

of the downrod onto the shaft using bolt, washer, 

spring  washer,  and  nuts.  Ensure  that  it  is  fully 

tightened 

 

3. 

Then put the cotter pin 

into the bolt hole and bend its two ends apart, to 

lock

 

4. 

Connect two wires (for phase 

(red wire) and neutral (black wire) connections) on 

the other side of the terminal block. Then insert the 

wires from the bottom side of the down rod to the 

top side 

5. 

Insert the bottom canopy 

(Top   and   bottom   canopies  are  identified  with 

 [Ref: Fig 1]

[Ref: Fig 2].

 

[Ref: Fig 3].

[Ref: Fig 4]. 

1.4. INSTALLATION INSTRUCTION

THERE  SHOULD  BE  NO  OBSTRUCTIONS 
FOR  THE  FAN  TO  ROTATE  AND  OBJECTS 
(LIKE  WALL,  OR  POST)  SHOULD  BE  AT 
LEAST 2 FEET (~61 CM) AWAY FROM THE 
TIP OF THE FAN LEAVES

B e f o r e   m a k i n g / r e m o v i n g   t h e  
connections  in  the  ceiling  rose,  please 
switch off the power.

orientation of Superfan logo) from the topside of 

the downrod. Insert the top canopy in an inverted 

manner

 

6.

 Fix the shackle kit in the 

ceiling hook 

 

7

. Fix the fan assembly in 

the shackle using bolt, washer, spring washer, nuts 

 

8.

  Then  tighten  the  nuts.  Put  the 

cotter pin into the bolt hole and bend its two ends 

apart  to  lock. 

9. 

Connect  the  phase  and  neutral 

wires coming out from the downrod to the ceiling 

rose as shown in the 

.

 Connect (Green/yellow) 

earth

 

wire

 

to 

  

the 

 

screw 

 

marked 

 

as

 

"      " on

 

 the

 

[Ref: Fig 5].

[Ref: Fig 6].

[Ref:  Fig  7].

Fig 8

Parameters

Input Voltage

(Vac)

Rated frequency

(Hz)

Span (mm)

Typical

Speed (rpm)

Typical Input

power (Watts)

Power factor

Air delivery

3

(m /min)

Speed control

Remote battery

160 to 265

48 to 52

1200

350

33

0.94

220

Super T2

Lithium coin battery 3V 165mAh

1200

385

33

0.94

230

Super T1

1400

275

38

0.94

270

Values

Super

A1

Super

X1

Super

V1

1

3

5

7

2

4

6

8

Отзывы: