Verona VEGCT212F SERIES Скачать руководство пользователя страница 15

15

b) Any conversion required must be performed by your dealer or a qualified licensed

plumber or gas service company. Please provide the service person with this
manual before work is started on the cooktop. (Gas conversions are the
responsibility of the dealer or end user.)

c) This cooktop can be used with NATURAL or LP/PROPANE gas. It is shipped from

the factory adjusted for use with NATURAL gas. 

d) Manifold pressure should be checked with a manometer; NATURAL gas requires

4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P (see figure 5.4).

Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than
the manifold pressure in order to check the regulator. 

The regulator used on this cooktop can withstand a maximum input pressure of
1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a step-
down regulator will be required.

e) The appliance, its individual shut-off valve, and pressure regulator must be

disconnected from the gas supply piping system during any pressure testing of
that system at pressures in excess of 1/2 PSI (3.5 kPa).

f) The appliance must be isolated from the gas supply piping system by closing its

individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa). 

3. Flexible Connections:

If local codes permit, CSA design-certified, flexible metal appliance connector is
recommended for connecting this cooktop to the gas supply line. Do Not kink or
damage the flexible connector when moving the cooktop. The pressure regulator has
3/8" NPT female pipe threads.You will need to determine the fittings required,
depending on the size of your gas supply line, flexible metal connector and shutoff
valve.

To mains

connection

To cooktop

Manifold
test point
pressure
1/8” NPT

Screw

Unscrew

Fig. 5.4

Содержание VEGCT212F SERIES

Страница 1: ...ces Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference The electr...

Страница 2: ...this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for the task it has...

Страница 3: ...rts Keep children away from the cooking hob when it is in use After use ensure that the knobs are in position OFF and close the main gas delivery valve or the gas cylinder valve In case of difficulty...

Страница 4: ...ce has a safety valve system fitted the flow of gas will be stopped if and when the flame should accidentally go out features CAUTION If the burner is accidentally extinguished turn the gas off at the...

Страница 5: ...the LO position Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positions and never between the maximum aperture and OFF...

Страница 6: ...non abrasive products Dry preferably with a chamois leather If acid substances such as lemon juice tomato conserve vinegar etc are left on the enamel for a long time they will etch it making it opaque...

Страница 7: ...ic ignition keep the electrode clean so that the sparks always strike Note To avoid damage to the electric ignition do not use it when the burners are not in place CORRECT REPLACEMENT OF THE BURNERS I...

Страница 8: ...alteration services or maintenance can cause injury or property damage Consult a qualified installer service agent or the gas supplier INSTALLATION INSTRUCTIONS TOOLS NEEDED FOR INSTALLATION Screwdri...

Страница 9: ...ance before servicing 9 When removing appliance for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Carefully lift applianc...

Страница 10: ...0 1 16 510 mm 2 23 64 60 mm 19 9 32 490 mm 2 23 64 60 mm 24 610 mm 10 5 8 270 mm 20 1 16 510 mm 1 31 32 50 mm 1 31 32 50 mm CUT OUT CUT OUT 2 23 64 60 mm 19 9 32 490 mm 2 23 64 60 mm 24 610 mm 10 5 8...

Страница 11: ...1 32 50 mm between the front side of the cooktop and the front of the countertop and also between the back side of the cooktop and the back of the countertop Important Base cabinet construction must a...

Страница 12: ...fluctuate with local demand The regulator supplied with this cooktop must be installed before any gas connections are made Use supplied pressure regulator only gas connection Explosion Hazard Use a ne...

Страница 13: ...not to damage the thread STEP 2 Mount the extension pipe to the elbow connection interposing the gasket supplied and tighten by using a wrench When tightening keep the elbow connection firm i e by usi...

Страница 14: ...cylindrical ISO 228 1 female 3 8 NPT conical male 3 8 NPT female 3 8 NPT female WARNING check the right positioning of the gas regulator The arrow on the back of the gas regulator must be oriented to...

Страница 15: ...mount a step down regulator will be required e The appliance its individual shut off valve and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of...

Страница 16: ...the cooktop All strains must be removed from the supply and fuel lines so cooktop will be level and in line Use joint compounds and gaskets that are resistant to action of natural or propane gas on a...

Страница 17: ...ulator at page 12 If the cooktop has been disconnected and then connected again to the gas supply line repeat the operations indicated in paragraph 5 Leak Testing at page 16 OPERATIONS TO BE PERFORMED...

Страница 18: ...ance be provided The outlet must be checked by a qualified electrician to see if it is wired with correct polarity This appliance when installed must be electrically grounded in accordance with local...

Страница 19: ...19 Wiring diagram key A Ignition coil PA Ignition switches group M Terminal block CA Igniter Fig 6 2 N L PA A CA M CA WIRING DIAGRAM...

Страница 20: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...

Отзывы: